l-com 16-CH User Manual page 34

H.264 digital video/audio recorders
Table of Contents

Advertisement

Video Loss Settings.. – used to setup the action settings when video loss is detected for
this camera. Press ENTER in Settings.. to call up Video Loss Setup display for the
camera. Please refer to
Section 6.2.1
for the details.
Motion Detection – whether the motion detection of this camera is enabled or not.
Press ENTER to check/uncheck this item. The default setting is "ˇ" - checked.
Motion Settings.. – used to setup the Motion Detection setting, for this camera. Press
ENTER in Settings.. to call up Motion Setup display for the camera. Please refer to
Section 6.2.2
for the details.
Covert – covert or not. If the camera is covert, the video of this camera can only be
seen if the user has logged in as Administrator. Press ENTER to check/uncheck this
item. The default setting is "–" - unchecked.
Call By Event – whether to switch the call monitor to the video of this camera if certain
event occurs for this camera. There are 4 options, including Off, Motion, Alarm, and
(Motion & Alarm). Press +/- buttons to select one.
Dwell Time – the dwell time if Call By Event is set to Motion, Alarm, or Both. Press
+/- buttons to adjust the value (3-60 seconds, discrete).
Audio – the AUDIO IN corresponding to this camera. The audio data for the selected
AUDIO IN will be recorded with the video data for this camera. Press +/- buttons to
select none (N/A) or AUDIO Inputs (1/2, 3/4). The default setting is "N/A".
Record Quality – the record quality for this camera. Press +/- buttons to select the
value (1-9, with 1 the lowest (rough) quality, 9 the highest (fine) quality).
Event Record IPS – the IPS (Images Per Second) for this camera if certain event
(Motion, Alarm) occurs for this camera. This camera will be recorded at this rate for
Post-record time since the event occurs. (Please refer to the following sections for
Post-record time.) Press +/- buttons to select the value (0 – 25 (PAL) / 30 (NTSC),
discrete).
Pre-record IPS – the pre-record IPS for this camera if certain event (Video Loss, Motion,
Alarm) occurs for this camera. This camera is recorded at this rate for Pre-record time
before the event occurs. (Please refer to the following sections for Pre-record time.)
Press +/- buttons to select the value (0 – Event Record IPS for this camera, discrete).
Normal Record IPS – the normal record IPS for this camera. This camera will be
recorded at this rate if no event occurs. Press +/- buttons to select the value (0 –
Pre-record IPS for this camera, discrete).