Advertisement

Items Relating to the Pulldown Control (Nos. A01 to ...)

Item number
Item
A01
PD TIME CODE
DISPLAY
A02
PD PRESET
FRAME MODE
A03
FC
SUPERIMPOSED
CHARACTER
A04
PD DF/NDF
SELECT
A05
PD EXT SD REF
LOCK MODE
Setting
Function
[off]
Sets whether or not to display the pulldown time code on the
time code display area.
on
off: Does not display the pulldown time code.
on: Displays the pulldown time code.
[24F FRAME MODE]
Selects the time code to be preset. The A frame of the
30F FRAME MODE
pulldown sequence can be preset.
24F FRAME MODE: The 24 frames time code is preset.
30F FRAME MODE: The 30 frames time code is preset.
[off]
Specifies whether or not to superimpose time data and
operating status information on the signal output from the
on
FORMAT CONV. OUT connector.
off: No information is superimposed.
on: Information is superimposed.
[drop frame]
Selects the running mode for the pulldown time code to be
preset.
non-drop frame
drop frame: Drop frame mode
auto
non-drop frame: Non-drop frame mode
auto: The unit switches the running mode (DF/NDF)
[off]
When the operating frequency is set to 23.98PsF, specifies
whether or not the pulldown output signal and down-
lock1
converted output signal are synchronized with the reference
lock2
signal by the REF. INPUT 2 connector.
off: The pulldown output signal and down-converted output
lock1: The pulldown output signal and down-converted
lock2: The pulldown output signal and down-converted
Notes
• A warning message appears when the HD reference
signal and REF. INPUT 2 reference signal are not input or
not synchronized.
• "lock1" and "lock2" are effective only when the operation
mode of this unit is set to 23.98/24PsF.
• When editing in 23.98/24PsF mode, with this unit as the
recorder and with "lock2" selected, phase synchronization
may not be achieved within 5 seconds. Also, edit In points
may be out of alignment. In these cases, select "off".
automatically according to the frame frequency of the
unit. When the frame frequency is 23.98 Hz, the unit
switches to the drop frame mode and switches to the
non-drop frame mode when it is 24 Hz.
signal are not synchronized with the reference signal by
the REF. INPUT. 2 connector.
output signal are synchronized with the reference signal
by the REF. INPUT 2 connector.
output signal are synchronized with the reference signal
by the REF. INPUT 2 connector. When the PB/EE
mode is selected, the amount of delay on the A frame of
the pulldown output signal for the A frame of the main
video signal is fixed to 2 frames (59.94i).
(Continued)
A-49
Appendix