TROUBLESHOOTING

Problem
Situation
No power
Faulty connection
Turn the Inverter power switch off, verify cables are tightly
connected to the Inverter and the power source.
output
Battery voltage below
Recharge or replace battery.
10 volts
Equipment being
Reduce the output load; DO NOT exceed maximum rating
operated draws too
for the Inverter.
much power
Inverter in thermal
Allow Inverter to cool down. Ensure there is adequate
shutdown condition
ventilation around the Inverter. Ensure that load is no more
than its maximum rating for continuous operation.
Low voltage
The input voltage at
Recharge/replace battery or add additional batteries. Turn on
alarm turns on
the input of the Inverter
the vehicle when using a 12V DC plug.
immediately
needs to be raised
Low voltage
Poor battery condition
Replace battery.
alarm is on all
with low input voltage
the time
Inadequate power or
Check condition of battery cables and cable leads. Clean or
voltage drops
replace as necessary.
Low power
Battery condition may
Recharge or replace battery.
output
be poor
Faulty connection
Make sure the battery and Inverter terminals are clean.
Inverter does
The internal protection
Contact Old World Industries.
not work after
has disabled the Inverter
connecting
the cables in
reverse
Action