SPECIFICATIONS

1.
Max output continuous power
2.
Max output peak surge
3.
north american Standard aC receptacles
4.
Max output current
5.
AC output voltage range
6.
AC output frequency range
7.
DC input voltage range
8.
Max no load current draw (12.8 V)
9.
Max input current consumption (12.8 V)
10.
Over voltage protection range
11.
Under voltage warning range
12.
Under voltage protection range
13.
Output overload protection range
14.
efficiency
15.
USB output
16.
Signal format
17.
Working temperature
18.
Storage temperature
19.
Storage air humidity
20.
DC fuse requirement for hard-wire installation
21.
Cable requirement @ 6 ft (1.8 m)
22.
Cable requirement @ 10 ft (3.0 m)*
23.
Weight
* For cable requirements greater than 10 ft (3 m), consult a licensed electrician.

TROUBLESHOOTING

Problem
Situation
Faulty connection
turn the Outlet power switch off; verify cables are tightly
No power
connected to the Outlet and the power source.
output
Battery voltage below
recharge or replace battery.
10 volts
Equipment being
reduce the output load; DO nOt exceed maximum rating
operated draws too
for the Outlet.
much power
Outlet in thermal
allow Outlet to cool down. ensure there is adequate
shutdown condition
ventilation around the Outlet. ensure that load is no more than
its maximum rating for continuous operation.
the input voltage at the
recharge/replace battery or add additional batteries. run the
Low voltage
input of the Outlet needs
vehicle engine when using a 12V DC plug.
alarm turns on
immediately
to be raised
poor battery condition
Replace battery.
Low voltage
with low input voltage
alarm is on all
the time
inadequate power or
Check condition of battery cables, cable leads and cable
voltage drops
clamps. Clean or replace as necessary.
Battery condition may
recharge or replace battery.
Low power
be poor
output
Faulty connection
Make sure the battery and Outlet terminals are clean.
the internal protection
Contact Old World industries.
Outlet does
has disabled the Outlet
not work after
connecting
the cables in
reverse
800 W
1600 W (0.1 sec)
2
≤8 a
105 - 125 V
60 ± 3 Hz
11 - 15 V
≤800 ma
≤80 a at 800 W
15.75 ± 0.75 V
10.5 ± 0.5 V
10.0 ± 0.5 V
840 - 1040 W
≥80%
5 V, 2.1 a
Modified sine wave
14°F to 104°F (-10°C to 40°C)
-4°F to 185°F (-20°C to 85°C)
10%-90%
200-amp anL
#2 aWG
00 aWG