Specifications; Troubleshooting - Peak PKC0AM Owner's Manual

100 watt power inverter
Table of Contents

Advertisement

SPECIFICATIONS

1.
Max output continuous power
2.
Max output peak surge
3.
North American Standard AC receptacles
4.
Max output current
5.
AC output voltage range
6.
AC output frequency range
7.
DC input voltage range
8.
Max no load current draw (13.8 V)
9.
Max input current consumption (13.8 V)
10.
Over voltage protection range
11.
Under voltage protection range
12.
Output overload protection range
13.
Efficiency
14.
USB output
15.
Signal format
16.
Working temperature
17.
Storage temperature
18.
Storage air humidity
19.
Dimensions (L x W x H)
20.
Weight

TROUBLESHOOTING

Problem
Situation
No power
Faulty connection
Twist Inverter slightly to ensure good contact.
output
Battery voltage below
Recharge or replace battery.
10 volts
Equipment being
Reduce the output load; DO NOT exceed maximum rating
operated draws too
for the Inverter.
much power
Inverter in thermal
Allow Inverter to cool down. Ensure there is adequate
shutdown condition
ventilation around the Inverter. Ensure that load is no more
than its maximum rating for continuous operation.
Low power
Battery condition may
Recharge or replace battery.
output
be poor
Faulty connection
Twist Inverter slightly to ensure good contact.
100 W
200 W (0.1 sec)
1
≤0.91 A
105 - 125 V
60 ± 3 Hz
11 - 15 V
≤0.6 A
≤8 A at 100 W
15.75 ± 0.75 V
10.0 ± 0.5 V
105 - 130 W
≥80%
5 V, 2.1 A
Modified sine wave
32°F to 104°F (0°C to 40°C)
-4°F to 185°F (-20°C to 85°C)
10%-90%
5.5 x 2.5 x 1.75 in.
0.4 lb / 0.18 kg