e
COMM ADJ (Communication Adjustment) : This function sets up the camera
communication status when controlling the camera through an external control device.
➊ When the SPECIAL menu screen is
displayed, press the Function Setup
switch so that the arrow indicates
'COMM ADJ'.
➋ Set up the mode using the Function
Setup witch.
-
CAM ID : Determines the camera's
identifi cation number
(between 0 and 255).
-
BAUD RATE : You can select 2400/48
00/9600/19200/38400/57600 bps.
-
UART MODE : You can select NONE, EVEN or ODD for the parity bits.
-
RET PKT : Determines whether to send a command back to the controller device
when a communication control command is sent to the camera.
-
DISP ID : Display camera title on top left corner of the screen.
-
PROTOCOL : You can select one of various protocols. SAMSUNG-T,
SAMSUNG-E, PELOC-D , PELCO-P, BOSCH, HONEYWELL,
VICON, PANASONIC.
Initial value of communication adjustment
Item
Initial value
LANGUAGE : You can select the menu language according to your requirements.
RETURN : Select this to save the SPECIAL menu settings and return to the MAIN
SETUP menu.
EXIT
Select a desired EXIT mode using the Function Setup Switch.
SAVE : Save the current settings and exit the MAIN SETUP menu.
NOT SAVE : Do not save the current settings and exit the MAIN SETUP menu.
RESET: Resets the camera settings to the factory defaults. Language,
Communication and Monitor Settings are not initialized.
Camera ID
BAUD RATE
1
9600
COMM SETUP
1. CAM ID
IIIIIIIIIIIIIIIIIIIIIIIIIIIII
2. BAUD RATE
9600
3. UART MODE
8-N-1
4. RET PKT
ENABLE
5. DISP ID
OFF
6. PROTOCOL
SAMSUNG-T
6. RETURN
UART MODE
PET PKT
8-NONE-1
ENABLE
English_31