Changing Dip Switch Settings; Changing The Pelco Address; Rs-485 Termination Resistor Dip Switch; Figure 8: Pc Board With Dip Switch Bank - FLIR D-Series Installation And Operation Manual

D-series
Hide thumbs Also See for D-Series:
Table of Contents

Advertisement

Connect the external cables to the electronic interface according to the following guidelines:
Power
RS485
Video
GND
Function
AC24V
B-
A+
GND
V+
V-
Screen
Cable
Red
Yellow
Blue
Red
Black
Core
Olivine
Color
Shield

5.2 Changing DIP Switch Settings

If needed, you may change the dip switch settings on the PC board. Figure 10 shows the
location of the DIP switches:

Figure 8: PC Board with DIP Switch Bank

The default settings are listed on Section 5.4 default Settings.

5.3 Changing the Pelco Address

The Pelco address (001-255) is set using DIP switch S2. See
section 8.4
for details.

5.4 RS-485 Termination Resistor DIP Switch

This is switch 8 on DIP switch S3. The switch is needed for when multiple cameras are wired in
a true RS485 "network", where the Pelco KBD (or similar controller device) uses addressable
commands from one access point. This switch needs to be set to the "On" position for the last
444-00001-00-10 Revision 100
Copyright © 2008 FLIR Systems, Inc.
Page 24 of 32