Connect the external cables to the electronic interface according to the following guidelines:
Power
RS485
Video
GND
Function
AC24V
B-
A+
GND
V+
V-
Screen
Cable
Red
Yellow
Blue
Red
Black
Core
Olivine
Color
Shield
5.2 Changing DIP Switch Settings
If needed, you may change the dip switch settings on the PC board. Figure 10 shows the
location of the DIP switches:
Figure 8: PC Board with DIP Switch Bank
The default settings are listed on Section 5.4 default Settings.
5.3 Changing the Pelco Address
The Pelco address (001-255) is set using DIP switch S2. See
section 8.4
for details.
5.4 RS-485 Termination Resistor DIP Switch
This is switch 8 on DIP switch S3. The switch is needed for when multiple cameras are wired in
a true RS485 "network", where the Pelco KBD (or similar controller device) uses addressable
commands from one access point. This switch needs to be set to the "On" position for the last