Optional Thermostat; Thermostat Installation - Enerzone BIO-45 MF Owner's Manual

Pellet stove
Table of Contents

Advertisement

THERMOSTAT INSTALLATION

OPERATING THE STOVE USING A THERMOSTAT
A thermostat may help you maintain a constant house temperature
automatically. A millivolt thermostat or 24 Volt thermostat is
required. A fixed wall mount or hand held model can be used. The
control panel can be set up two ways to operate your stove in
thermostatic mode.
THERMOSTAT INSTALLATION
Unplug the stove from the power outlet.
Connect two thermostat wires to the terminal block located on
the lower right side of the back of the stove. To do so, loosen
the two screws and insert the wires in the terminals. Tighten
the two screws. (See figure 16)
If you are using a wireless wall thermostat or a hand held
thermostatic remote control, you can locate the receiver behind
the stove's back panel, on the right end side, just below the
terminal block.
Most receivers are already equipped with
quick-connect terminals. Simply unplug the PC board wires
connected to the back of the terminal block and connect them
directly with the receiver's terminals.
thermostat is very important to obtain the best comfort and
efficiency from you BIO-45 MF.
mounted 50 inch from the floor on a wall located 15 to 20 feet
from the stove. You should avoid an installation directly in front
of the stove to avoid cycling.(See figure 17)
MODES
THERMOSTATIC MODE
To use this mode, the "MODE" button must be pushed to
"Thermostat" upon starting the stove. The heat setting is then
selected using the "Heat Level" selector "+ or –". When set in
thermostatic mode, the stove will automatically run a the heat
level selected until the set room temperature is reached. When
that occurs, the stove will switch to heat setting #1 (lowest) until
the thermostat calls for heat again. The convection blower will
also slow to its lowest speed. When the thermostat calls for
heat again, the stove will increase its feed rate to match the
heat setting selected.
N.B.:
If the room temperature remains stable and the
thermostat does not call for heat during at least 45 minutes,
the stove will shut down. When the thermostat calls for heat
again, the stove will start an ignition cycle. Once the ignition
cycle is completed, the stove
match the heat setting selected.