SERVICE CALL CHECK

Check the following before calling service:
1. Does the display light when the door is opened and closed?
2. When the door is opened, is the oven lamp switched on?
3. Place one cup of water (approx. 250 ml) in a glass measure in the oven and close the door securely.
Oven lamp should go off if door is closed properly.
Programme the oven for one minute on Microwave 100%. At this moment:
A. Does the oven lamp light?
B. Does the cooling fan work?
(Put your hand over the ventilation openings.)
C. Does the Microwave icon
D. After one minute, did an audible signal sound?
E. Is the water inside the oven hot?
4. Remove water from the oven and programme the oven for 5 minutes on Convection, Oven 250°C.
A. Does the Convection icon
B. After the oven stops, is the inside of the oven hot?
5. Fill the water tank with water and replace.
Operate the oven for 3 minutes on Manual Steam High.
A. After the oven stops, is the inside of the oven filled with steam?
If "NO" is the answer to any of the above questions, please check your wall socket and the fuse in your meter box.
If both the wall socket and the fuse are functioning properly, CONTACT YOUR NEAREST SERVICE CENTRE
APPROVED BY SHARP.
IMPORTANT: If the display shows nothing even if the power supply plug is properly connected, the Energy Save
Mode may be in operation. Open and close the oven door to operate the oven. See "Getting Started" on page 9.
NOTES:
1. If time in the display is counting down very rapidly, check Demonstration Mode. (Please see page 23 for detail.)
2. If the oven is set for more than about 8 minutes on Microwave 800W power level, output power will be reduced
to avoid overheating. Finally the output power will be 600W after 9 minutes.

SPECIFICATIONS

AC Line Voltage
AC Power Required
Microwave
Convection
Output Power
Microwave
Convection
Steam heating element
Microwave Frequency
Outside Dimensions
Weight
When tested in accordance with AS/NZS 2895.1.2007.
*
This is the classification of ISM (Industrial, Scientific and Medical) equipment described in the International
**
Standard CISPR11.
The depth does not include the door opening handle and knob.
***
appear on the display?
appear on the display?
: Single phase 230 - 240V, 50Hz.
:
1.16 kW
1.55 kW
:
*
800 W
(IEC test procedure)
1.45 kW
1.25 kW
**
: 2450 MHz
(Class B/Group 2)
: 553 mm(W) x 438 mm(H) x 483 mm(D)
: Approx. 24 kg
29
Yes _______
No _______
Yes _______
No _______
Yes _______
No _______
Yes _______
No _______
Yes _______
No _______
Yes _______
No _______
Yes _______
No _______
Yes _______
No _______
Yes _______
No _______
Yes _______
No _______
***