Table Of Zones; Troubleshooting - Hornet 742T Installation Manual

Car security
Table of Contents

Advertisement

t t a a b b l l e e o o f f z z o o n n e e s s
When using the Diagnostic functions, use the Table of Zones to see which input has triggered the system. It is
also helpful in deciding which input to use when connecting optional sensors and switches.
Z Z O O N N E E N N O O . .
T T R R I I G G G G E E R R T T Y Y P P E E
1
Multiplex
2
On-board impact sensor
3
Two-stage, progresses from
warning to full alarm
5
Two-stage, progresses from
warning to full alarm
N N O O T T E E : The Warn-away response does not report on the LED.
t t r r o o u u b b l l e e s s h h o o o o t t i i n n g g
■ D D o o o o r r i i n n p p u u t t d d o o e e s s n n o o t t i i m m m m e e d d i i a a t t e e l l y y t t r r i i g g g g e e r r f f u u l l l l a a l l a a r r m m . . I I n n s s t t e e a a d d , , f f i i r r s s t t I I h h e e a a r r c c h h i i r r p p s s f f o o r r 3 3 s s e e c c o o n n d d s s : :
That's how the progressive two-stage door input works! This is a feature of this system. This is an instant trigger,
remember, since even if the door is instantly re-closed, the progression from chirps to constant siren will con-
tinue.
■ C C l l o o s s i i n n g g t t h h e e d d o o o o r r t t r r i i g g g g e e r r s s t t h h e e s s y y s s t t e e m m , , b b u u t t o o p p e e n n i i n n g g t t h h e e d d o o o o r r d d o o e e s s n n o o t t : :
Have you correctly identified the type of door switch system? This often happens when the wrong door input has
been used. (See H1/5 GREEN Door Trigger Input, Primary Harness Wire Connection Guide section of this guide.)
■ S S y y s s t t e e m m w w i i l l l l n n o o t t p p a a s s s s i i v v e e l l y y a a r r m m u u n n t t i i l l i i t t i i s s r r e e m m o o t t e e l l y y a a r r m m e e d d a a n n d d t t h h e e n n d d i i s s a a r r m m e e d d : :
Are the door inputs connected? Is the H1/6 blue wire connected to the door trigger wire in the vehicle? Either
the H1/5 green or the H1/7 violet should be used instead. (See Primary Harness Wire Connection Guide section
of this guide.)
3 3 2 2
I I N N P P U U T T D D E E S S C C R R I I P P T T I I O O N N
H1/6 BLUE wire. Connects to optional hood/trunk pins or
an optional sensor. Inputs longer than 0.8 seconds will
instantly trigger the full alarm sequence and report Zone 1.
Second-stage of on-board impact sensor (heavy impacts
from impact sensor).
Door switch circuit. H1/5 GREEN or H1/7 VIOLET.
Ignition. H1/9 YELLOW.
© 2004 Directed Electronics, Inc. Vista, CA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents