Removing the BioClip plug

To change a Combi unit from BioClip function to cutting unit
with rear ejection, remove the BioClip plug located under the
unit with three screws.
Combi 103
1 Put the unit in the service position, see Placing in the
service position.
2 Remove the three screws holding the BioClip plug, and
remove the plug.
3 Tip: Fit three full-thread screws M8x15 mm in the screw
holes to protect the threads.
4 Replace the unit in normal position.
Fit the BioClip plug in the reverse order.
Combi 94
1 Put the unit in the service position, see Service position
for the cutting unit.
2 Loosen the knob and the bolts holding the BioClip plug
and remove the plug.
3 Replace the unit in normal position.