Camera Address Set; Communication Protocol Set; Baud Rate Setting - Veilux SVEX-Q18 User Manual

Intelligence camera set
Table of Contents

Advertisement

4.2.2

Camera Address Set

Decimal system is used for camera address, K1、K2、K3 dip switches are for address setting. K1 stands for
the unit digit, K2 is for tens digit and K3 for hundreds digit. Other K4 is for baud rate and K5 for control protocol.
e.g if the camera address is No.2, the K1 needs be 1 and K2, K3 should be 0, see below table:
Dip Switch
Address
If the camera address is No.138, the K1 needs be 8, K2 is 3 and K3 should be 1, see below table:
Dip Switch
Address
4.2.3

Communication Protocol Set

Check the protocols in the control system and then set K5 as below table. The new setting will work after
power on again.
4.2.4

Baud Rate Setting

Set baud rate with K4 as below table. The new setting will work after power on again.
K3
K2
0
0
K3
K2
1
3
Table 2: Protocol setting (K5)
Dip Switch
1
2
Table 3: Protocol setting (K4)
Dip Switch
0
1
2
3
4
5
SVEX-Q18 Explosion proof Camera Manual
K1
2
K1
8
Protocol
PELCO-P
PELCO-D
Baud Rate
Remote Control
1200
2400
4800
9600
19200