Remote Control Setting; Osd Menu Function; Flameproof Structure - Veilux SVEX-Q18 User Manual

Intelligence camera set
Table of Contents

Advertisement

4.2.5

Remote Control Setting

When K4 is "0", camera address, control protocol and baud rate can be set with OSD Menu (the default
baud rate is shown on the display when power is on). At this time, the setting of K1, K2, K3 and K5 won‟t work.
Setting process is as below: Go to preset 95, press MAIN MENU
5.

OSD MENU FUNCTION

OSD MENU is available for this camera. You can enter OSD like this: when camera power is on, go to No.95
preset and the main menu will be shown. Then the "UP", "DOWN", "LEFT", "RIGHT", "IRIS OPEN" and "CLOSE"
in the control part will turn into the menu control key, the other keys of control part will not work. When :<>" is
shown, it means there is a slave menu. "UP" and "DOWN" can choose the menu; while "LEFT" and "RIGHT" can
change the specification. "OPEN" means OK and it can go into the slave menu as well. When the menu item is
used, it will glitter.
When system is in scan mode, "RETURN: CLOSE" will be shown in the lower left corner of display. You can
quit with "IRIS CLOSE" and then control the camera.
6.

FLAMEPROOF STRUCTURE

z
Completely consider the explosive air getting into ex-proof structure, which may lead to explosion because
of some reason and to confirm and ensure camera explosion proof performance based on its structure gap,
length and max temperature it will get to.
z
Enclosure shall burden water pressure testing for 1.5Mpa for 10~12 seconds without leakage as pass,
which is ordered in GB3836.2-2000.
z
Camera surface temperature max shall not over 80℃ while it is working.
z
Window glass adopts steel glass to burden Impact and Heat change testing.
z
Enclosure protection to IP67
Cable for Camera uses inlaid device to tighten its screw and nut and make cable tight and no move.
SVEX-Q18 Explosion proof Camera Manual
CONTROL
RS485.
Book
Ver: 0.1
18

Advertisement

Table of Contents
loading

Table of Contents