Install / Service Menus; Setup - Thermostat; Equipment Summary Menu; Install Menu - Carrier Infinity Control Installation Instructions Manual

Systxccuiz01 - b infinity control
Hide thumbs Also See for Infinity Control:
Table of Contents

Advertisement

NOTE: Override time will not appear if programming has been
turned off.
4. You can change the temporary override time in 15- -minute
increments by pressing the TIME (+/- -) button until the de-
sired override time is selected, or press the HOLD button
anytime to override the schedule indefinitely.
Quick Program Schedule For All Days
This section will give you a quick program schedule for ALL
DAYS of the week. For more information on how to create
customized schedules for every day, the entire week, or weekend,
refer to the Owner's Manual.
1. Flip down the door at the bottom of the control.
2. Press the SCHEDULE button, which allows you to create
one schedule for the entire home.
3. Press either the LEFT or RIGHT side button repeatedly (if
necessary) until "ALLDAYS" is displayed. The WAKE
time period will be highlighted.
4. Using the TIME (+/.) button, set the start time for this time
period.
5. Press the red HEAT button. Heating temperature will begin
flashing.
6. Set the heating temperature using the TEMP (+/.) button.
7. Press the blue COOL button. Cooling temperature will be-
gin flashing.
8. Set the cooling temperature using the TEMP (+/.) button.
9. Set the remaining periods by using the SCROLL button to
select "DAY", "EVENING", and "SLEEP".
10. To copy a zone, use SCROLL button to select "COPY".
Select YES and copy this zone schedule to other zones us-
ing NO or YES.
11. Exit the scheduling mode by either closing the door or
pressing the SCHEDULE button.
12. If changes are made, you will be asked to "SAVE
CHANGES YES/NO."

INSTALL / SERVICE MENUS

The "INSTALL / SERVICE" menus contain a set of vital
information. This information enables the Installer or Service
person to view a summary of what has been installed, etc. This
information is not covered in the Owner's Manual.
To enter INSTALL / SERVICE menus, press and hold the
ADVANCED button for at least ten seconds. The following menu
will appear (See Fig. 24):
INSTALL/SERVICE
EQUIPMENT SUMMARY
INSTALL
SETUP
CHECKOUT
SERVICE
SOFTWARE VERSION 1
EXIT
Fig. 24 - - Install / Service Menus
NOTE: The INSTALL / SERVICE menu will automatically exit
after 60 minutes of no push button activity.
EQUIPMENT SUMMARY: Shows all equipment recognized by
and attached to the system.
INSTALL: Used when adding, changing out, or un- -installing
equipment.
SETUP: Used to view or modify equipment settings.
CHECKOUT: Allows testing of equipment operation
SERVICE: Used to view operation and fault history of equipment
and enter dealer name/phone number for display
SELECT
A03200

EQUIPMENT SUMMARY MENU

EQUIPMENT SUMMARY
FURNACE
AC
FILTER
HUMIDIFIER
UV LIGHTS
ZONES
BACK
Fig. 25 - - Equipment Summary
This screen shows indoor unit type and model number, outdoor
unit type (and model number if a 2- -stage unit), filter type and any
accessories that are installed, and how many zones are recognized.

INSTALL MENU

INSTALL
TO ADD, UNINSTALL OR
RE-INSTALL EQUIPMENT,
PRESS RIGHT SIDE
BUTTON
BACK
Fig. 26 - - Install Menu
This menu item will perform start- -up process in order to learn all
equipment in system. Press right side button to initiate the process.
See Fig. 26.

SETUP MENU

SETUP
THERMOSTAT
FURNACE
HEAT PUMP
ZONING
ACCESSORIES
SYSTEM MAINTENANCE
BACK
Fig. 27 - - Setup Menu
This menu has several layers, allowing modification of equipment
settings. No settings will need to be made at equipment (i.e. DIP
switches on a furnace). All configuration settings made effective
from this menu will override equipment configuration made by dip
switches. Fig. 27 shows all the information that can be found in the
SETUP menu.
Setup - - Thermostat
Auto Mode Setup:
S Enable/Disable Auto Changeover mode (default=Enable).
S Auto Changeover Time may be adjusted 5 to 120 minutes,
(default = 30 minutes).
When Auto mode is enabled (factory default) a change from heat
to cool (or vice versa) will not occur until an opposite mode
demand has existed for 30 minutes. If the setpoint is changed, the
30 minute timer is deleted.
Heat/Cool Deadband:
S 0 to 6_F / 0 to 3_C, (default = 2_F).
The minimum difference enforced between heating and cooling
desired temperatures. This can allow one setting to "push" the
other to maintain this difference.
9
58MVB0100-12
24ANA136A003
EAC
YES
YES
1234
A07117
INSTALL
A03202
SELECT
A04089

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Infinity systxccuiz01-b

Table of Contents