INTRODUCTION

The Infinity Zone System consists of several intelligent
communicating components which includes the Infinity Zone
Control (or User Interface), Smart Sensors, Damper Control
Module, variable speed furnace or FE fan coil, 2- -stage AC or HP
and Infinity Packaged Products, which continually communicate
with each other via a four- -wire connection called the ABCD bus.
Commands, operating conditions, and other data are passed
continually between components over the ABCD bus. The result is
a new level of comfort, versatility, and simplicity.
All Infinity furnaces or fan coils are variable- -speed and
multi- -stage for maximum flexibility, efficiency, and comfort. They
support controlled ventilation, humidification, dehumidification,
and air quality control. Either an Infinity 2- -stage (communicating),
or a standard 24VAC controlled outdoor unit may be used.
When using conventional outdoor units, the Infinity furnace or fan
coil provides the 24 volt signals needed to control them. Also, the
Infinity Damper Control Module (P/N SYSTXCC4ZC01) allows
connection of a Carrier HRV or ERV without the need for a
separate wall control.
All system components are controlled through the wall mounted
Infinity Zone Control, which replaces the conventional thermostat
and provides the homeowner with a single wall control for all
features of the system.
Design Considerations
The Infinity Zone system is unique because a bypass damper must
not be used. This is possible due to the intelligence of the system
and
variable
speed
motor
applications, the following parameters should always be met:
1. Zones should be sized so that each zone can deliver at least
the minimum airflow for the system in both heating and
cooling modes.
2. Oversize duct work by 25% to avoid excess noise at mini-
mum zone airflow.
3. Be aware that heating airflow may be higher than cooling
airflow depending on equipment combination.
INSTALLATION AND START- - UP
OVERVIEW
This instruction covers installation of the Infinity Zone Control
only. Physical installation instructions for the indoor and outdoor
equipment, Damper Control Module, and accessories are provided
with each unit.
Setup, commissioning, operation, and troubleshooting of the
Infinity Zone System are covered in this installation instruction. It
is the guide to connecting the system components and
commissioning the system once all physical components are
installed. Special screen prompts and start- -up capabilities are
provided in the Infinity System to simplify and automate the initial
commissioning of the system.
S Install Infinity Zone Control according to this instruction.
S Install indoor unit, outdoor unit, and accessories according to
their instructions.
S Wire complete system according to this instruction.
S Setup, commission, and operate system according to this
instruction to assure a smooth and trouble free start- -up.

INSTALLATION

Check Equipment and Job Site
Inspect equipment. File claim with shipping company prior to
installation if shipment is damaged or incomplete.
technology.
For
trouble- -free
Infinity Zone Control Location and Wiring
Considerations
WARNING
!
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury
or death.
Disconnect power before routing control wiring.
All wiring must comply with national, local, and state codes.
Infinity Zone Control Location
The Infinity Zone Control User Interface is the command center for
the Infinity Zone System and is typically located in Zone 1 to sense
and control temperature in this zone. It should be located where it
is easily accessible and visible to the adult homeowner or end user.
For accurate temperature measurement, the following guidelines
should be followed:
The Infinity Zone Control and Room Sensors should be mounted:
S Approximately 5 feet (1.5 meters) from the floor.
S Close to or in a frequently used room, preferably on an inside
partitioning wall.
S On a section of wall without pipes or ductwork.
The Infinity Zone Control and Room Sensors should NOT be
mounted:
S Close to a window, on an outside wall, or next to a door leading
to the outside.
S Exposed to direct light or heat from a lamp, sun, fireplace, or
other temperature- -radiating objects which could cause a false
reading.
S Close to or in direct airflow from supply registers.
S In areas with poor air circulation, such as behind a door or in an
alcove.
Remote Room Sensor Option
A Remote Room Sensor can be used with the Infinity Zone
Control to take the place of the User Interface internal temperature
sensor. This allows the Infinity Zone Control to be mounted in
areas with less than optimal airflow (such as near an exterior door,
window or in a closet). The remote sensor can be wired to the
terminal block connectors labeled S1 and S2 at the User Interface
backplate, or the OS1 and OS1C connection at the Damper Control
Module. In either case, the Infinity Zone Control will automatically
detect the Remote Room Sensor and ignore its internal temperature
sensor. It is also important to note the humidity sensor cannot be
remotely located, so do not locate the Infinity Zone Control in an
area where humidity sensing may not be accurate.
NOTE: S1 & S2 connection on User Interface backplate is now
used for Remote Room Sensor, NOT for OAT Sensor hookup.
In addition, the Remote Room Sensor is a temperature sensor only,
having no additional user inputs. This sensor is typically connected
to the Damper Control Module and used to sense and control
temperature in each zone.
Remote Sensor Averaging
Typically, one Remote Room Sensor is used per zone, but multiple
sensors may be used and averaged in some applications. Averaging
requires a special series- -parallel wiring method with a specific
number of sensors. See Fig. 2 in this manual for wiring diagram.
2