alternate power supply must generate the same voltage, phase, and
frequency (Hz) as shown in Table 9 or the furnace rating plate.
Power from an alternate power supply that is non-sinusoidal may
damage the furnace electronics or cause erratic operation.
VOLTS---
HERTZ---
UNIT SIZE
PHASE
40,000
115--- 60--- 1
60,000
115--- 60--- 1
80,000
115--- 60--- 1
100,000
115--- 60--- 1
120,000
115--- 60--- 1
* Permissible limits of the voltage range at which the unit operates satisfactorily.
# Unit ampacity = 125 percent of largest operating component's full load amps plus 100 percent of all other potential operating components' (EAC, humidifier,
etc.) full load amps.
Time ---delay type is recommended.
{
Length shown is as measured one way along wire path between furnace and service panel for maximum 2 percent voltage drop.
}
J-BOX
LOCATIONS
J−BOX
MOUNTING
SCREWS
J−BOX
MOUNTING
BRACKET
GROUND
SCREW
J−BOX COVER
Fig. 31 - - Installing J- -Box (When Used)
Table 9 – Electrical Data
OPERATING VOLTAGE
MAXIMUM
RANGE*
UNIT
AMPS
Maximum*
Minimum*
127
104
127
104
127
104
127
104
12.2
127
104
12.2
A11299
Contact the alternate power supply manufacturer for specifications