Configuration (Setup)

NOTE: Menus shown in this document reflect
FIRMWARE VERSION R2.1.0.9 or later.
Actual context-sensitive screens are
dependent on firmware version, FlexStat
model, and options selected.
NOTE: If
appear at the top of the screen
(such as in the Main Menu), scroll up or
down to see the rest of the menu's off-
screen choices.

Main Menu Overview

MAIN MENU
ABOUT
ADVANCED
ALARM
DATE/TIME
SCHEDULE
SETPOINTS
SYSTEM
Navigate the menus and change settings by press-
ing a combination of buttons. Press the:
Enter button to select and/or exit value editing.
Up/Down button to move among entries (up/
down lines).
Left/Right button to move among value fields
(left/right spaces).
Left button to return to the Home screen.
NOTE: A log-in may be required to access menu
items.
SETPOINTS
SAVE CHANGE?
COOL SETPT:
HEAT SETPT: 67° F
YES
COOL SETBACK: 80° F
When prompted about a change (on any menu),
press Right/Left to select the desired choice and
then Enter.
FlexStat
NO

About the FlexStat

ABOUT FLEXSTAT
MODEL: BAC–141136CE
FW: FLEXSTAT R1.3.0.0
APP: AIR HANDLER
OPT: MOD H / MOD C
MORE
These display-only screens show the following
information on various menus (select MORE and
then the relevant category to see them all).
• Model number
• Firmware (FW) type and version (see
Upgrade on page
• Application configuration and options (set in the
Application menu—see
and Additional Setup on page
MORE: Communication
• Device instance (set in the Device menu—see
(Advanced) BACnet Device Properties on page
• MAC address, IP address, and/or Subnet
address (set in the Communications menu—see
(Advanced) Communications (BACnet) on page
MORE: Firmware
• Firmware type, version , and build date (see
Firmware Upgrade on page
• Application software version (ASV)
NOTE: ASV will show CUSTOM if any built-in
Control Basic program (1–5) is not running
or has auto-run disabled. A + sign with
a number indicates the custom program
number currently running (e.g., +8+9
indicates Programs 8 and 9 are running).
See
(Advanced) CB (Control Basic)
Programs on page
MORE: Hardware
• Model number
• Serial number of unit
• Board revision
MORE: Uptime (the amount of time since the last
reset)
6
MORE ABOUT
COMMUNICATION
FIRMWARE
HARDWARE
UPTIME: 28D 00:32:57
Firmware
29)
(Advanced) Application
7)
29)
10.
Operation Guide, Rev. R
17)
14)

Advertisement