3
Pull the fuser unit lock control lever (blue)
in the direction of the arrow.
Fuser unit
lock control
lever (blue)
4
Grip the handle of the fuser unit, pull it out
carefully, and place it on a flat surface.
Note
• Make sure the fuser unit does not hit the LED head.
The fuser unit can be extremely hot,
Warning
and there is a risk of getting burned.
LED head
5
Pull the jam release lever downward, and
slowly pull the jammed paper out in the
direction of the arrow (toward you).
Jam release lever
6
Hold the handle of the fuser unit, and gently
replace it inside the device.
Handle
Handle
- 7 -
7
Push the fuser unit lock control lever (blue)
toward the back to lock it in place.
Fuser unit
lock control
lever (blue)
8
Close the top cover.
9
Return the document holder to its original
position. Press the top of the document
holder into place.
Document
holder
This completes the procedure.
Note
• After removing jammed paper from the fuser unit, print
several blank pages, as stray toner is sometimes left
inside the fuser unit.
When a Paper Jam Occurs