Step 2: Connect to gas supply
step 2: connect to gas supply
1. The inlet to the appliance is ISO 7
1. The inlet to the appliance is ISO 7
- Rp
" internal thread situated
1
- Rp ½" internal thread situated
2
towards the top right hand rear
towards the top right hand rear corner.
corner.
2. Fit the bayonet connection to the wall
2. Fit the bayonet connection to the
in the shaded area as shown.
wall in the shaded area as shown.
The shaded area shown is applicable to
installations in minimum depth cabinets.
The
shaded
applicable to installations in
If more room is available, the bayonet
minimum depth cabinets.
fixing area can be extended, provided that
the flexible tube does not obscure the fan
If more room is available, the
intake.
bayonet fixing area can be
extended,
provided
flexible tube does not obscure the
fan intake.
60mm
rear
60mm
wall
square
3. Use a 900mm - 1125mm length of
flexible connector.
connector shall be fitted such that
it cannot come into contact with a
3. Use a 900mm - 1125mm length of
flexible connector. The flexible
moveable part of the housing unit
connector shall be fitted such that it
(eg; drawer) and does not pass
cannot come into contact with a
through any space susceptible of
moveable part of the housing unit (eg;
becoming congested. Make sure
drawer) and does not pass through
that the flexible connector does not
any space susceptible of becoming
congested. Make sure that the flexible
block the cooling fan inlet.
connector does not block the cooling
fan inlet.
installation instructions
Installation Instructions
area
shown
is
that
the
60
mm
The flexible
25
4. Flexible
connections
4. Flexible connections should comply
comply with BS 669. Parts of the
with BS 669. Parts of the appliance
appliance likely to come into
likely to come into contact with a
contact with a flexible connector
flexible connector have a temperature
rise of less than 70°C.
have a temperature rise of less
than 70˚C.
5. Rigid connections must be accessible
to disconnect for servicing. Cut a
5. Rigid connections must be accessible
150mm square hole in the right hand
to disconnect for servicing. Cut a
rear corner of the support shelf for the
150mm square hole in the right
supply pipe.
hand rear corner of the support
6. Make sure all connections are gas
shelf for the supply pipe.
sound.