Interdigit Timer; Offhook Idle Time; Offhook Warning Tone Time; Fxs Port - Patton SmartLink 4020 User Manual

Analog voip soho router
Table of Contents

Advertisement

SmartLink 4020 User Manual
7 • System

Interdigit Timer

The number of seconds the SmartLink 4020 will wait for the caller to input a subsequent digit of the dialed
number. If the timer value is exceeded before the dial plan is matched (see section
"Gateway Settings"
on
page 49), the busy tone will be played to the caller.

Offhook Idle Time

If the handset is off-hook with no dialing activity for longer than the time specified, then the busy tone will be
played. The default is 6000 ms (6 seconds).

Offhook Warning tone time

If the handset is off-hook with no dialing activity for longer than the time specified, then the off-hook warning
tone will be played. The default is 12000 ms (12 seconds). This value should be greater than the off-hook
idle time (see section "Offhook Idle Time").

FXS Port

Choose the correct country for a proper impedance match.
Figure 47. FXS Port Polarity Configuration section of Localization window

FXS port Input Gain

Adjust the input gain level for FXS port.

FXS port Output Gain

Adjust the output gain level for FXS port.

Caller ID Method

Specifies the country-specific Caller ID format.

"Call Progress Tones" Synchronization

When "Call Progress Tones" Synchronization is selected, the Caller ID presentation method value is used to
automatically set the county-specific call progress tones.

Ring Setting

Figure 48. Ring Setting section of Localization window

Ring Waveform

Specify the ring tone waveform.
Localization