TROUBLESHOOTING

Problem
Generator will not start
Generator will not start;
Generator starts but runs roughly
Generator shuts down during operation
Generator cannot supply enough power or
overheating
No AC output
Generator gallops
Repeated circuit breaker tripping
for further technical support:
Technical Service
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)
Toll Free: 1-877-338-0999
tech@championpowerequipment.com
21
REV 42436-20130424
Cause
No fuel
Faulty spark plug
Unit loaded during start up
Low oil level
Choke in the wrong position
Spark plug wire loose
Out of fuel
Low oil level
Generator is overloaded
Insufficient ventilation
Cable not properly connected
Connected device is defective
Circuit breaker is open
Faulty brush assembly
Loose wiring
Other
Engine governor defective
Overload
Faulty cords or device
ENGLISH
Solution
Add fuel
Replace spark plug
Remove load from unit
Fill crankcase to the proper level
Place generator on a flat, level surface
Adjust choke
Attach wire to spark plug
Fill fuel tank
Fill crankcase to the proper level. Place
generator on a flat, level surface
Review load and adjust. See "Power
Management"
Check for air restriction. Move to a well
ventilated area
Check all connections
Replace defective device
Reset circuit breaker
Replace brush assembly (Service Center)
Inspect and tighten wiring connections
Contact the help line
Contact the help line
Review load and adjust. See "Power
Management"
Check for damaged, bare or frayed wires.
Replace defective device
42436