Electrical installation
Warning! Only a qualified person must do
the electrical installation.
The manufacturer is not responsible if you
do not follow safety precautions from the
chapter "Safety information".
This appliance is supplied without a main plug
or a main cable.
Cable
Cable types applicable for installation or re-
placement: H07 RN-F, H05 RN-F, H05 RRF,
H05 VV-F, H05 V2V2-F (T90), H05 BB-F.
For the section of the cable refer to the total
power on the rating plate.
Connecting the terminal board
The appliance has a six-pole terminal board.
The jumpers (bridges) are set for operation on
a 400 V three-phase with a neutral wire.

Environment concerns

The symbol
on the product or on its
packaging indicates that this product may not
be treated as household waste. Instead it
should be taken to the appropriate collection
point for the recycling of electrical and
electronic equipment. By ensuring this product
26
A
B
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
If the mains voltage is different, rearrange the
jumpers on the terminal board (refer to the con-
nection diagram below). Connect the ground
cable to the terminal. After you connect the
supply cable to the terminal board, attach it
with a junction clamp.
is disposed of correctly, you will help prevent
potential negative consequences for the
environment and human health, which could
otherwise be caused by inappropriate waste
handling of this product. For more detailed
information about recycling of this product,
1
2
3
= earth cable
1 2 3 4 5
230V 3~
L1
1 2 3 4 5
230V 1~
L1
1 2 3 4 5
400V 2N~
L1
L2
1 2 3 4 5
400V 3N~
L1 L2 L3
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
4
L2
L3
PE
N
PE
N
PE
N
PE
www.zanussi.com