Corner Installations

A typical 45° installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still
apply).
(a) Corner to Wall (minimum)
(b) Corner to Center of Flue (typical)
b
a
© Travis Industries
Installation
(for qualified installers only)
42PB
56" (1423mm)
20-3/4" (528mm)
Minimum 1/2" (13mm) Clearance
NOTE ON PIPE SHIELD:
When venting in a corner
application, one side of the pipe
shield may be disconnected from
the top of the fireplace and bent
at a 45° angle.
4/19/23 - 1453
54PB
63-3/4" (1619mm)
25" (635mm)
PB 42 & 54 MV/GSB2/GSR2 Install