Invacare
- Dragon Vertic
· Depending on the type of control arm bracket fitted to the wheelchair, remove the screws using
the cross point screwdriver. Remove remote
· Remove the joystick knob (2) by firmly pulling upwards (if required). To access the gaiter.

22.4.2.2 Power Module and ALM

· Gain access to the power module as described in the Battery section of this manual
· Unplug the remaining connectors from the power Module.
· Unplug the ALM module (4) connectors. Use the terminal screwdriver to release the wires
where required.
· Grasp the power module (3) & fixing plate and firmly pull upwards to dislodge the hook and loop
faster strip. Remove this assembly, noting its position.
· Remove the two screws using a screw driver and a 7 mm open ended spanner in one position.
The power module is now free and can be removed from the fixing plate.
· Locate the ALM Fixing plate nuts, and using the 8 mm spanner undo the two nuts and remove
the ALM and plate.
· The ALM is removed from the plate by using a screwdriver and 8 mm open ended spanner

22.4.3 Assembly

· To re-assemble reverse the above steps, ensuring that all fixing holes are aligned. Take care
not to over tighten the fixing screws.
NOTE:
When fitting the joystick remote screws (2) be sure not to use a torque in excess of 2 Nm.

22.4.4 Pilot Plus Power Module Connector Orientation

Position:
A Bus Cable Port
B M1 Motor Cable (RH Motor)
C Battery Cable
D M2 Motor Cable (LH Motor)
E Bus Cable Port.
F Actuator / Lighting Ports