Ir Control Connections; Ir Receiver / Ir Input To Room Connections; Connecting To An Ir Automation System/Connecting Block; Stereo To Mono Ir Adaptor - Binary B-300-HDMATRIX-4x4 Owner's Manual

Binary hdmatrix switcher
Table of Contents

Advertisement

5 IR CONTROL CONNECTIONS

CAUTION: Before connecting an IR Receiver or an IR Automation System, verify that the HDMa-
trix is OFF to avoid damaging the unit.

5.1 IR RECEIVER / IR INPUT TO ROOM CONNECTIONS

Pin out configurations for IR receivers and Automation Systems vary. Before connecting to this input, review
this section carefully in order to match the pin outs for the HDMatrix.
IR Signal
(Tip)

5.2 CONNECTING TO AN IR AUTOMATION SYSTEM/CONNECTING BLOCK

When connecting to an IR Automation System or connecting block, the 12V DC (Sleeve) must not be connected.
Connections of this type require the use of the included Stereo to Mono IR Adaptor or a custom-made cable. A mono
3.5mm cable should not be used as it will short out the 12 VDC to GND and will make the connection inoperable.

5.2.1 Stereo to Mono IR Adaptor

To B-300-HDMATRIX

5.2.2 Custom Cable Construction

To B-300-HDMATRIX
© 2012 Binary
GND
(Ring)
12V DC (Sleeve)
GND (Ring)
IR Signal (Tip)
IR Signal
(Ring)
12V DC (Sleeve)
(Sleeve)
GND (Ring)
IR Signal (Tip)
B-300 HDMATRIX Installation and Users Manual 4X4 & 8X8
12v DC
(Sleeve)
IR Signal
GND
12v DC
To IR Control System/
Connecting Block
(Tip)
(Tip)
GND
12V DC
Tip
Ring
Sleeve
GND (Sleeve)
IR Signal (Tip)
To IR Control System/
Connecting Block
GND (Sleeve)
IR Signal (Tip)
pg.9