Trouble Shooting / Accessories - Airrex HSC-36 User Manual

Table of Contents

Advertisement

TROUBLE SHOOTING
TROUBLE
NOT
● Cord correctly connected
WORKING
● POWER button "OFF"
● Fuse (supply) blown
● Breaker on switch board
● Ambient temp. too high
POOR
● Filter blocked with dust
COOLING
● Dust in heat exchanger
● Obstacle against inlet side
● Ambient temp. too high
ACCESSORIES
ITEM
DUCT
COLD
AIR
DUCT COVER
OUTLET
(FINISHING COLLAR)
CASSETTE
HOT
AI R
CASSETTE
EXHAUST
12
CHECK
tripped
(over 104℉)
(over 104℉)
1.6ft.
Diam.
6.9inch.
9.8ft.
FILTER
FILTER
● Connect cord correctly
● Press POWER button to "ON"
● Exchange fuse in board
● Check load capacity a`nd reset
● Use only below 104℉
● Clean Filter
● Clean heat exchanger
● Remove and allow 20inch clearance
● Use only below 104℉
MODEL
HSC-36/60/70
OPTION
REMEDY
DRAWING

Hide quick links: