Page 1
AIR CONDITIONER MODEL: HSC-12L/HSC(O)-14 USER'S MANUAL HSC(O)-18/HSC(O)-24A LOUVER TYPE NOZZLE TYPE HSC-12L HSC-14/18/24A HSCO-14/18/24A ▶ It is ESSENTIAL that you read ‘NOTES ON SAFETY’ carefully ▶ Thank you for purchasing the AIR CONDITIONER. before use and follow them at all times.
TABLE OF CONTENTS ■ SAFETY INSTRUCTIONS ■ GENERAL ADVICE BEFORE USE ■ EXTERIOR DESCRIPTION ■ SPECIFICATIONS ■ CONTROL PANEL FUNCTIONS ■ MODE CHANGING METHOD ■ HOW TO SET THE 'OFF'TIMER ■ TEMPERATURE CONTROL OPERATION ■ SELECTION OF LOCK OR UNLOCK ■...
SAFETY INSTRUCTIONS The following instructions are to ensure user’s safety and to prevent any physical injury or material damage. Please read carefully and follow all instructions. There are two sections to these instructions: WARNING and CAUTION. The following symbols are for your guidance: = You must NOT.
SAFETY INSTRUCTIONS CAUTION Do not place AIR CONDITIONER on uneven, unstable or inclined surface. (This could cause malfunction) When storing the AIR CONDITIONER, keep it in a dry, cool place. (To prevent corrosion and malfunction) If not being used for some time or if lightening is present, always disconnect from power. (To prevent risk of electric shock, short circuit or fire) Do not spray water onto the AIR CONDITIONER nor use solvents such as benzene, thinner or alcohol for cleaning.
EXTERIOR DESCRIPTION ※ HSC-12L FRONT VIEW FLEXIBLE DUCT OUTLET (COLD AIR) LOUVER OUTLET (COLD AIR) DIGITAL CONTROLLER EVAPORATOR FILTER (INSIDE) CONDENSED WATER TANK TO COLLECT WATER GENERATED DURING COOLING. CASTERS (FRONT LOCKABLE) BACK&SIDE VIEW CONDENSER OUTLET (HOT AIR) CONDENSER FILTER...
Page 6
EXTERIOR DESCRIPTION ※ HSC(O)-14 & HSC(O)-18 & HSC(O)-24A FRONT VIEW ① Cool Air Ooulet ① ① ② ② ② Handle ③ Digital Controller ③ ③ ④ Electrical Access panel ④ ④ ⑤ Power Plug ⑥ Fire Alarm Connection Port ⑤ ⑤...
CONTROL PANEL FUNCTIONS ※ HSC-12L ⑪ ⑧ ⑨ ⑧ ⑫ ⑨ ⑩ ⑥ ⑦ ③ ⑤ ④ ② ① ① Power : Use to power On / Off. ② ∨ ∧: Raises or lowers setting temperature and/ or sleep (off) time.
Page 9
CONTROL PANEL FUNCTIONS ※ HSC(O)-14 & HSC(O)-18 & HSC(O)-24A ⑧ ⑨ ⑦ ⑩ ⑨ ⑤ ⑧ ⑥ ⑪ ④ ③ ① ② ① Power : Use to power on / off. ② ∨ ∧ Button : Raises or lowers temperature and/ or sleep (off) time. ③...
MODE CHANGING METHOD COOLING MODE If you press 'cool' button. 'COOL' is displayed. then LED is on. DEHUMIDIFIER MODE When the cooling is operating, If you press the 'cool' button. 'dEHU' is displayed. then LED is on. FAN MODE When the Dehumidifier is operating. If you press the 'cool' button, 'FAn' is displayed.
HOW TO SET THE ‘OFF’ TIMER. This function enables you to set the length of time you want the AIR CONDITIONER to operate. You can set the time period from 30min. to 24 hours in 30min. and 1 hour increments. 1.
TEMPERATURE CONTROL OPERATION ※ HSC-12L 1. When turn ON, the setting temperature is displayed. 2. When you push either ▼ or ▲ button, the setting temperature is changed. Mode Display range Setting range Room Temp 32℉~99℉ 64℉~86℉ Spot Temp 32℉~99℉...
SELECTION OF LOCK OR UNLOCK 1. When turn OFF If press '∨' for 5 seconds, 2. You can set 'UNLOCK' or 'LOCK' after pressing you can control 'LOCK, UNLOCK' mode. '∧' button. 3. When You set 'LOCK' there will be '.' below the nember in the screen.
Check refrigerant level and/or refrigerant leak. If the AF sensor is short Exchange temperature sensor circuited or cut 'E3&1' (Contact Airrex U.S.A. at 1-888- AF sensor displayed and the 'Error' 535-8841) LED will be on. If the RT sensor is short Exchange temperature sensor circuited or cut 'E3&2'...
Page 15
Check Filters Evaporator/Condenser Check Evaporator/Condenser Coils Check refrigerant level and/or refrigerant leak. Exchange temperature sensor Temperature sensor has Sensor (Contact Airrex U.S.A. at 1-888- an electric short. 535-8841) Problem Condensate tank is full Empty the water tank Water full Do not use the unit in an ambient Evaporator is below 25 ℉...
Fire Alarm & Error Signal Connection FIRE ALARM SIGNAL CONNECTION Input Terminal FA1 and FA2 When the signal from the fire alarm system is received, the air conditioner turns off and does not operate until the unit has been RESET. Connecting the fire alarm wire from fire alarm system 1.
Ambient temp. too high ℉ Use only below Cooling & Dehumidifier 113 ℉ ℉ (Cooling & Dehumidifier: over 113 or 104 ℉ (HSC-12L) or 104 (HSC-12L) Filter blocked with dust Clean Filter Dust in heat exchanger Clean heat exchanger POOR...
MAINTENANCE ※ HSC-12L CLEANING THE AIR FILTERS 1. To remove EVA filters, open the front grille ① and pull the filter inside ②. 2. To remove COND filters, slide up a little ① and pull towards you ②. 3. Clean the filters with water or compressed air.
WARRANTY (Applicable to first retail purchaser only) AIRREX HEAT PUMP give the more reliable performance, comfort and durability the more they are used. They are built under a strict quality assurance regime which includes inspection both during and after production and exhaustive reliability testing.
Need help?
Do you have a question about the HSC-12L and is the answer not in the manual?
Questions and answers