Trouble Shooting / Accessories - Airrex HSC-14 User Manual

Airrex air conditioner
Hide thumbs Also See for HSC-14:
Table of Contents

Advertisement

TROBULE SHOOTING
TROUBLE
K REMEDY
NOT
● Power plug correctly connected
WORKING
● POWER button "OFF"
● Blown fuse in electric panel
● Fuse (supply) blown
● Breaker on switch board
tripped
● Ambient temp. too high
(over 105℉)
POOR
● Filter blocked with dust
COOLING
● Dust in heat exchanger
● Obstacle against inlet side
● Ambient temp. too high
(over 105℉)
ACCESSORIES
ITEM
Diam.
DUCT
5inch
DUCT COVER
COLD
(FINISHING COLLAR)
AIR
OUTLET
DAMPER BASE
(FLOW CONTROL FLAP)
ALUMINIUM FILTER
CASSETTE
HOT
ALUMINIUM FILTER
AIR
CASSETTE
EXHAUST
CHEC
MODEL
HSC-14/18/24/24A
12inch
OPTION
9.8 ft.
● Connect plug correctly
● Press POWER button to "ON"
● Replace fuse
● Exchange fuse in board
● Check load capacity and reset
● Use only below 105℉
● Clean Filter
● Clean heat exchanger
● Remove and allow 50cm.clearance
● Use only below 105℉
DRAWING
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsc-18Hsc-24Hsc-24a