Tensioned Advantage
240V Wiring Diagram
IMPORTANT NOTE: The wall switch is REQUIRED to make any
limit switch adjustments, EVEN if a third party control system is
used. Therefore, it is advised to wire the switch or provide a
4-conductor connection that is accessible.
Blue (Common)
Power Input
Brown (Hot)
240VAC / 50Hz
Green
240V Wiring Diagram with Optional Built-in Video Projector Interface
CAUTION: The projector must be turned off before
connecting the trigger wires to the projector. Failure to
do so may damage the controller.
1. Use 2-conductor 20-24 gauge wire to extend the low voltage
connection from the projector's 5 or 12-volt screen trigger
output to the length required to reach the VPI. When
extending the low voltage connection from the projector's
screen trigger output, be sure to maintain the proper polarity.
The red wire from the VPI is the "signal" and the black wire
from the VPI is the "ground".
240VAC/ 50Hz
Power Source
Front of Wall
Back of
Switch
Wall Switch
8
Electrol
Installation for 220/240V Screens
®
®
Motor
Green
Ground to Case
NOTE: Ground–Must be
Connected to Building
Ground
Brown (Hot)
Green/Yellow
(Ground)
Blue (Common)
White
Red
Black
ILT RJ-9 Pin-Outs
IR or Up
Ground Common
Data or Down
RJ9
RJ9
Splitter
Dry Contacts
2. Connect the wires from the VPI that are labeled "Low Voltage
Connection" to the end of the extended screen trigger wires
above.
IMPORTANT NOTE: The wall switch is REQUIRED to make
any limit switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire the switch or
provide a 4-conductor connection that is accessible.
Black
Red
(Tab Is Facing Up)
Black
Red
Green
+5V
White
UP
UP DN
STOP
3-POSITION
DOWN
SWITCH
Front of Wall
Back of
Switch
Wall Switch
Green/Yellow (Ground)
Brown (Down)
Blue (Common)
Black (Up)
5/12 Volt Screen Trigger
on Projector
GND
+5V
RJ9