Theory Of Operation; Overview; Rcu20 Major Assemblies; Central Processing Unit (Cpu) Board - Comtech EF Data Radyne RCS20 Installation And Operation Manual

M:n redundancy switch
Hide thumbs Also See for Radyne RCS20:
Table of Contents

Advertisement

Chapter 3. Theory of Operation
3.1

Overview

This chapter provides additional basic information on the RCU20, DDS20, and IFS20 hardware
and internal operation.
3.2

RCU20 Major Assemblies

The RCU20 Redundancy Control Unit contains the modules that control and monitor the
operation of the M:N Switch System. The RCU20 is composed of the following major assemblies
and components:
Central Processor Unit (CPU) Board
Front Panel Board
Controller Interface Module
Clock Distribution Module (optional)
Redundant Power Supplies
Ethernet Module (optional)
Bank Control Module

3.2.1 Central Processing Unit (CPU) Board

The Central Processor Unit (CPU) Board contains the M:N Switch intelligence and memory
circuitry. The on-board microprocessor is an MC68302, which has a 24-bit address bus and a 16-
bit data bus. The microprocessor controls and coordinates all major functions of the Switch and
performs all necessary calculations. The non-volatile system memory on the board stores the
switching parameter settings for each Modem Channel. Control and data signals are routed to the
appropriate devices in the system through various latches and transceivers that are controlled by
the microprocessor.
3–1