  • Page 1 Grid Tie DC-AC Inverter Owner's Please read this manual before Manual Pure Sine Wave operating your Inverter Model: Soleil 2000-120 Soleil 2000-240...
  • Page 2 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS To reduce the risk of electrical shock and to ensure safe installation and operation of Soleil 2000, please carefully read and strictly follow all safety instructions and cautionary markings. Warning : This marking indicates very important safety warning for user to appropriately apply during installation or operation.
  • Page 3 Caution : This unit is provided with fixed trip limits and shall not be aggregated above 30kW on a Single Point of Common Connector. Caution : The AC output of this unit is not bonded to ground. Caution : The input and output circuits are isolated from the enclosure.
  • Page 4: Table Of Contents

    Table of contents 1. Introduction ……………………………………………………. 5 2. Installation …………………………………………………..6 3. Wiring process …………………………………………………10 4. Operating procedure…………………………………………..15 5. System Structure……………………………………………… 21 6. Electrical Specifications……………………………………….20 7. Trouble shooting………………………………………………..24 www.samlexamerica.com Toll free 1-800-561-5885...
  • Page 5: Introduction

    1. Introduction Product features Full DSP digital control PV Module Wp=2.5kW Power output capacity: 2KW/120Vac 60Hz Maximum power conversion efficiency >94% (without Isolation Transformer) High efficiency maximum power point tracking function LCD displays system function and power generating status Real time network monitoring and recording function Computer can perform system setup of photovoltaic inverter and recording of...
  • Page 6: Installation

    2. Installation Warning : All electrical installation shall be done in accordance with local and national codes ANSI/NFPA 70. Warning : Connecting the Soleil 2000 to the electrical grid shall only be performed by qualified personnel and only after formal approval from the utility company.
  • Page 7 eventually damage the electronics that are sensitive to humidity. Ambient temperature should be between –20°C and +50°C.  Heat sink may reach over 70 C, so pay special attention to air circulation for sufficient  heat dissipation. For indoor unit, please provide external ventilation. Mounting of Soleil 2000 ...
  • Page 8 Metal fixing plate Fig. 2-3: Side view of the unit mounting to the wall Secure screw www.samlexamerica.com Toll free 1-800-561-5885...
  • Page 9 Mounting of Soleil 2000  Place the metal fixing plate on the designated surface of the wall and mark the holes of the screw.  Drill the holes and hammer in the wall anchors.  Place the metal fixing plate again and fasten the four screws into their respective holes Fig.
  • Page 10: Wiring Process

    3. Wiring process The photovoltaic inverter wiring is as shown above. Warning : National Electrical Code (NEC) requires that the inverter be connected to a dedicated circuit and no other outlets or device may be connected to this circuit. See NEC Section 690-64(b) Warning : Follow local electrical codes and the National Electrical Code (NEC), ANSI/NFPA 70.
  • Page 11 Caution : Longer wire or Voltage drop would require that larger wire sizes be used. For a 70 feet (16.4 m) cable, use size of AWG 12 For a 100 feet (33 m) cable, use size of AWG 10 Notes for wiring AC Output 1/2”...
  • Page 12 Connecting AC Wiring  Make sure AC Main Breaker is at OFF position.  Install a 1/2 inch conduit fitting to the AC knockout at the left side of the Soleil 2000.  Install two 1/2 inch conduit fittings respectively to the two knockouts at the bottom of isolation transformer located just left side of the Soleil 2000.
  • Page 13 Ground DC Input AC Output Connecting DC Wiring Make sure that AC main breaker and DC disconnect breaker are at OFF position. Install a 3/4 inch conduit fitting to the DC knockout at the right side of the Soleil 2000. Install a 3/4 inch conduit between the DC knockout and the DC disconnect breaker panel.
  • Page 14 Connect the cable to the appropriate port of the communication PWB in the unit. Connect the other end of the cable to the appropriate port of the PC. Make sure the conduit fitting or cable grand on the knockout is sealed and safe from rain Replacing the cover After AC, DC and Communication wires are all connected, make sure the Isolation sheet with cautionary markings covers over the power circuitry below and no pressure will be...
  • Page 15: Operating Procedure

    4. Operation Warning : Connection between the Soleil 2000, the PV string and the utility grid must be done in the order described bellow. Operation ignoring the order will cause hazardous accident. Start operation Verify all breakers are at OFF position. Use an electricians’...
  • Page 16 Monitoring and setup RS-232Use standard DB9 cable to connect serial port on the computer to that on the machine. After complete setting of COM Port following Monitoring Software, it is ready to start monitoring and setting up the photovoltaic inverter. For monitoring and setting up the photovoltaic inverter, please refer to the “Monitoring software manual”.
  • Page 17: Control Panel

    Control Panel Switch ON photovoltaic inverter Switches the photovoltaic inverter ON. Switch ON photovoltaic inverter When solar panel input voltage reaches the required range for starting, press this button for a few seconds until a buzzing sound is audible. Release the button. LCD panel will show the starting screen. After power grid detection runs for 5 minutes and remains in “normal”...
  • Page 18 Status reports from LCD Boot up screen 1. Switch on the power grid circuit breaker, the screen shows “Ver. 10”(Pic-1) 2. DSP initial boot up sequence completed as shown on (Pic-2), notified by half a second “beep” sound. The system Pic -1 is ready and enters idle mode.
  • Page 19 MPPT Mode 1. Under the initial mode, after pressing “POWER” button for more than 3 seconds, or, after DSP takes 5 minutes to detect and confirm that the voltages of power grid and solar module are in operating range, the unit will beep for 1.5 Pic-7 seconds and switch on the system.
  • Page 20 Protection mode fault display 1. Under conditions as voltage too high, current overflow or inappropriate frequency, the unit will switch off PWM immediately and relay jump off to enter fault mode as shown on (Pic-11) to (Pic-16). Pic - 11 A.
  • Page 21: System Structure

    5 System structure System structure block diagram System structure can be divided into the following sections: 1. Inverter: By using SPWM control and parallel circuit control technology, the inverter can invert electricity from DC into AC and feeds current into AC grid directly. 2.
  • Page 22: Electrical Specifications

    6. Electrical specifications Item Data Comment Description Converter Topology Full-Bridge DC-AC converter Architecture Control Processor DSP (TI TMS320LF2407A, 40MHz) Maximum Input voltage 450Vdc Voltage Range 200~360Vdc (120V mode) PV Input Grounding DC Negative ground Input Current Ripple < 200mA Number of Phase Single Phase ■...
  • Page 23 Item Description Data Comment Anti-Islanding DC Input Over Voltage and Under Voltage Input Over Current AC Output Over Voltage and Under Voltage Output Over Current DC Ground Fault Detect Protection and Interruption Current Limiting Power Limiting Frequency Decrease and Frequency Increase Internal Shutdown Internal protection tripping relay IEEE C62.41.2 : 2002...
  • Page 24: Trouble Shooting

    7.Trouble shooting Problem Possible causes How to correct Output/Input current OVER CURRENT  Check the output stage of PV inverter for short over supply circuit or inappropriate wiring  Check if PV Inverter is placed in a well-ventilated area LINE FREQ ERROR Power grid ...