5116 Azusa Canyon Road Irwindale, CA 91706 Tel. 626-962-7770 Fax. 626 962-7720 he information contained herein is the property of FALCON ® ELECTRIC INC., is proprietary, confidential, and not to be disclosed, disseminated or used except for the purpose provided.
Operational Mode Table . Chapter 6, Maintenance & Technical Support Care & Maintenance Battery Life vs. Temperature Battery Replacement Storing the UPS and Batteries . FCC . Technical Support & RMA Procedure . Requesting Technical Information or Support. FALCON Web Support...
CAUTION This UPS utilizes voltage that may be hazardous. Do not attempt to disassemble . This unit contains no user replaceable parts. Refer all servicing to Falcon Electric, Inc. CAUTION This UPS is not intended to be used in conjunction with life support or operating room equipment.
ED Series represents one of the smallest and most compact units of the FALCON ® UNINTERRUPTIBLE POWER SYSTEM (UPS) product line. In the tradition of all FALCON ® products, it maintains the highest reliability and the most complete on-line, sinewave power protection available. An on- line, sinewave UPS is the only total solution to virtually any power problem.
If the unit is overloaded, it will shutdown completely if the overload is not corrected within 15 seconds. FIGURE 1: FALCON ED SERIES BLOCK DIAGRAM EMERGENCY BYPASS LINE...
MODEL SELECTION GUIDE U N I T N AM E ED 1000R M - 1 ED 2000R M - 1 ED 2400R M - 1 ED 2500R M - 1 N om i nal VA 1000 2000 2400 2500 C ur r ent - I nput 10.
To file a claim for shipping damage or concealed damage: 1) File with the carrier within 15 days of receipt of the equipment; 2) Send a copy of the damage claim within 15 days to the Falcon ® Service Department.
UPS is overloaded or has failed. Should this occur, check the load level and correct any overload condition if present. During this condition, UPS load outlets will be powered by filtered utility bypass power.Should the unit not be overloaded, call FALCON ® support for further assistance..
TYPICAL UPS REAR PANEL LAYOUT DB-9F CONTACT CLOSURE INTERFACE This connector gives access to the UPS contact closure status interface. Please reference page 8 of this manual for details. Inlet for Input Line Cord on ED1000-1 only. Line cord permenently attached to ED1500-1 and ED2000-1.
CHAPTER CHAPTER OPERATION The FALCON ® ED unit is very simple to use. Verify the power cord is plugged into the correct voltage power source. Activate the power switch to the "ON" position. The green AC LED illuminates. The green INV LED illuminates.
To escape this condition, the problem must first be corrected then turn the UPS power switch "OFF", then back "ON". It is recommended that you leave the ED unit power switch "ON" at all times and switch your devices "OFF" individually. This will insure that your batteries are always at a maximum charged state.
C. Spent batteries must be recycled in accordance with all Federal, State and local laws. To locate a recyaling center near you contact the Falcon service department. CAUTION A.
The following precautions should be observed by a qualified technician when working with batteries. Remove watches, rings, or other metal objects. Use tools with insulated handles. Wear rubber gloves and boots. Do not lay tools or metal parts on top of batteries Storing the UPS and Batteries Should you need to store the UPS for a long period, fully recharge the battery just prior to storage and recharge the battery every 6 months by plugging the...
You may request technical information or support by Email or telephone. Please send your technical or support questions by Email to: SUPPORT@FALCONUPS.COM You may contact a FALCON support engineer directly by calling the FALCON support line between 9:00 am and 4:00 pm PST. 626.962.7770 FALCON Web Support Product data sheets, specification and owner’s guides are available in Adobe...