Freestanding Minimum Clearances; Learances Rom Tovepipe - HearthStone Shelburne 8371 Owner's Manual

Woodstove
Table of Contents

Advertisement

Hearthstone Quality Home Heating Products, Inc ®
F
M
REESTANDING
INIMUM
Installation type
No stove heat shields &
Single wall connector
Rear heat shield &
Single wall connector
Rear heat shield &
Double wall connector
Unprotected Surfaces
Min. Width Max. Depth
69 in.
42 in.
(1750-mm)
(1065-mm)
C
F
LEARANCES
ROM
Minimum Clearance to Combustibles
Connector type
No heat shields
Double wall connector
Connector type
Single wall connector pipe
Double wall connector pipe
Single wall connector is 24 MSG or 25 MSG
blued steel stovepipe.
Double wall connector (close clearance pipe)
which must be used with a listed factory-built
"Type HT" chimney and may also be used with a
masonry chimney to reduce clearances, is
available from several manufacturers, your
dealer can help you choose. Some air insulated
connector pipe models available are Simpson
Dura Vent DVL and Metalbestos DS. Security,
GSW and Ameritec also have acceptable close
clearance connector pipe.
When used in a mobile home, a spark arrester is
required. (See page 17)
Chimney connector shall not pass through floor
or ceiling, nor any attic or roof space, closet or
C
LEARANCES
To Combustibles
Unprotected Surfaces
Parallel
Side
18 in.
24 in.
(460 mm)
(610-mm)
21 in.
18 in.
(535 mm)
(460-mm)
21 in.
12 in.
(535 mm)
(305-mm)
Allowable Alcove Dimensions
Min. Height
(stove to ceiling
above.)
36 in.
(915-mm)
S
TOVEPIPE
Unprotected Surfaces (vert.) Protected Surfaces (NFPA 211) (vert.)
18-in. 460-mm
6-in. 150-mm
Unprotected Surfaces (horiz.) Protected Surfaces (NFPA 211) (horiz.)
18-in. 460-mm
6-in. 150-mm
(from closest point of stove)
Protected Surfaces (NFPA 211)
Corner
Rear
13 in.
6 in.
(330-mm)
(150-mm)
13 in.
6 in.
(330-mm)
(150-mm)
6 in.
6 in.
(150-mm)
(150-mm)
Protected Surfaces (NFPA 211)
Min.
Max.
Width
Depth
39 in.
34-in.
(990-mm)
(865-mm)
(from Chimney Connector)
6-in. 150-mm
2-in. 50-mm
9-in. 230-mm
3-in. 75-mm
similar concealed space.
through a wall or partition of combustible
construction is desired, the installation shall
conform to NFPA 211 or CAN/CSA - B365.
It is very important to follow minimum clearances
for chimney connectors to combustibles such as
walls and ceilings when installing the stove near
non-combustible surfaces.
connector clearances are outlined below. The
single wall clearances are generic; the Double
wall clearances are for Simpson Dura Vent DVL,
CHECK
THE
MANUFACTURER
12
Shelburne Model 8371
Parallel
Side
Rear
12 in.
5 in.
(305-mm)
(130-mm)
9 in.
3 in.
(230-mm)
(75-mm)
3 in.
3 in.
(75-mm)
(75-mm)
Min. Height
(stove to ceiling above.)
18 in.
(460-mm)
Where passage
Typical chimney
SPECIFICATIONS
FROM
OF
YOUR
CONNECTOR.
Corner
THE

Hide quick links: