appliances, smell, do not operate properly,
suffer smoke roll-out when opened, or back-
draft whether or not there is combustion
present.
3. Opening a window slightly on a calm
(windless) day alleviates any of the above
symptoms.
4. The house is equipped with a well-sealed
vapor barrier and tight fitting windows and/or
has any powered devices that exhaust
house air.
5. There
is
excessive
windows in the winter.
6. A ventilation system is installed in the
house.
If these or other indications suggest that infiltration
air is inadequate, additional combustion air should
be provided from the outdoors. Outside combustion
air can be provided to the appliance by using the
optional outside air kit 93-53700.
P
C
ERIODIC
HECKLIST
Perform each of these tasks at the specified
intervals.
Weekly:
Empty ashes from the firebox and ash pan,
sooner if the firebox or the ash pan begins to fill
up.
Monthly:
Visually inspect chimney connector and chimney
for creosote; clean accordingly.
Bi-monthly:
A visual inspection of the chimney connector
and chimney for creosote is recommended
depending upon your use of the stove. (Refer to
page 23 – Creosote Formation and Need For
Removal)
Check door seals using the "dollar bill test." -
When the fire is out and the stove is cool, shut
the door on a dollar bill.
without any resistance, then your stove's door
isn't sealed properly.
change the door gasket. (Refer to page 23 –
Gaskets)
Seasonally:
Dismantle the chimney connector and clean it
thoroughly. Replace any pieces that show signs
of rust or deterioration.
Inspect and, if necessary, clean your chimney.
condensation
on
If the bill pulls out
To tighten the seal,
Thoroughly clean out the inside of the stove.
Inspect all door gasket material and replace if
worn, frayed, cracked or extremely hard.
E
P
MERGENCY
ROCEDURES
If you have a stovepipe (connector) or chimney fire,
follow these instructions:
1. If the fire is too threatening, leave the area and
call the fire department immediately!
perform the next three steps.
2. Close the primary air control.
3. Close the stovepipe damper (if present).
4. Keep the stove front, side and ash doors closed!
WARNING: DO NOT ATTEMPT TO PUT OUT A
STOVEPIPE OR CHIMNEY FIRE BY THROWING
WATER ONTO THE STOVE, STOVEPIPE, OR
CHIMNEY.
TEMPERATURE ASSOCIATED WITH SUCH FIRES
CAN CAUSE INSTANTANEOUS STEAM AND
SERIOUS BODILY HARM.
Once the chimney fire has expired, leave the primary
air control closed and let the fire in the stove die out
completely. The stove should not be fired again until
the stove, stovepipe, and chimney are all thoroughly
inspected for any sign of damage. You must correct
any damage before using your stove again.
H
'
EARTHSTONE
B
S
AFFLE
YSTEM
To enhance the combustion efficiency and reduce
the emissions of the fire in your stove Hearthstone
has developed an advanced THERMO-CERAMIC
baffle system. This system uses a lightweight,
durable ceramic material above the burner tubes to
maintain the high temperatures in the secondary
combustion area and maintain the low emission –
high efficiency combustion you desire. This material
will not corrode, rust, dissolve or lose its strength,
however it is vulnerable to puncture or cracking due
to rough handling.
PLEASE
EXERCISE
WOOD OR CLEANING YOUR STOVE, NOT TO
DAMAGE THE Thermo-Ceramic BAFFLE
Located directly above the burner tubes in the
firebox, this white, gray, or brown sheet of material
will break if wood or cleaning brushes impact it. Be
careful when loading and cleaning your stove to not
break this material. If this piece is fractured or a hole
is punctured, it will cause the stove to function
improperly. You must replace the board through a
qualified Hearthstone dealer.
6
Shelburne Model 8371
THE
EXTREMELY
T
-C
S
HERMO
ERAMIC
CARE
WHEN
LOADING
If not,
HIGH

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents