Mantel And Wall Projections - Heat & Glo GRAND-I35-C Owner's Manual

Gas ?replace
Table of Contents

Advertisement

1-1/2 IN.
SURROUND
Location
A
Alternate Unit Width
D
B
Alternate Unit Depth
D
C
Alternate Unit Height
D
* Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum
fi replace height for bends in vent pipe.
Figure 5.3 Fireplace Opening - Deep Surround
B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Clearance to combustible material under the insert is 1/4
inch (6 mm). Clearance from top of fi replace opening for
combustibles extending 12 inches max. is 12 inches.
• Use leveling legs to raise insert minimum 1/4 inch (6 mm)
above combustible material or outer wrap of factory built
fi rebox.
Combustible facings must not extend behind the insert
surround. For non-combustible material specifi cations
refer to section 1.E.
20
Heat & Glo • Grand-I35-C, Grand-I35-SP, Supreme-I30-C, Supreme-I30-SP • 2206-901 Rev. P • 6/14
SIDE VIEW
B
D
C
APPLIANCE
MINIMUM FIREPLACE SIZE
Inches
33-3/16
15-1/16
22-9/16
TOP VIEW
D
SURROUND
GRAND-I35-C
Millimeters
843
383
573
EXISTING NON-COMBUSTIBLE FACING
Figure 5.4 Mantel Clearances
A
D
APPLIANCE
SUPREME-I30-C
Inches
Millimeters
29-1/16
738
13-7/8
352
19-1/16
484
12 IN. MAX.
10 IN. MIN.
2 IN.
MAX.
12 IN. MIN.