Before Lighting Fireplace - Heat & Glo GRAND-I35-C Owner's Manual

Gas ?replace
Table of Contents

Advertisement

4. If you intend to use both an optional wired wall switch
and the RC300 remote control to operate your fi replace,
the wall switch will override any commands given by
the remote.
MODULE
FLAME HI/LOW
STATUS
SWITCH
INDICATOR LED
Figure 2.3 Control Module
5. Module Reset
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into lock-out
mode by emitting three audible beeps, then continuously
displaying a RED/GREEN error code at its status
indicator LED.
Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section G.
Locate the module selector switch. (See Figure 2.3).
Set the module selector switch to the OFF position.
• Wait fi ve (5) minutes to allow possible accumulated gas
to clear.
Set the module selector switch to ON or REMOTE
position.
Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod-
ule reset switch more than one time within a fi ve minute
time period. Gas may accumulate in fi rebox. Call a quali-
fi ed service technician.
Nine Hour Safety Shutdown Feature
The appliance has a safety feature that automatically
shuts down the fi replace after nine hours of continuous
operation without receiving a command from the wall
switch or optional remote.
Heat & Glo • Grand-I35-C, Grand-I35-SP, Supreme-I30-C, Supreme-I30-SP • 2206-901 Rev. P • 6/14
SELECTOR
SWITCH
NG/LP GAS-TYPE
SELECTOR SWITCH
I. Before Lighting Fireplace
Before operating this fi replace for the fi rst time, have a
qualifi ed technician:
• Verify all shipping materials have been removed from
inside and/or underneath the fi rebox.
• Review proper placement of logs, ember material and/
or other decorative materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire/Asphyxiation! DO NOT oper-
ate fi replace with fi xed glass assembly removed.
Determine if this fi replace has a standing pilot or an
Intellifi re ignition system. Ask your dealer or open control
access panel, look at gas valve.
• A standing pilot ignition will have a red or black ignitor
button (refer to Figure 2.4).
• An Intellifi re ignition system will not have a button.
RED OR BLACK IGNITOR BUTTON
Figure 2.4 Ignitor Button
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grand-i35-spSupreme-i30-spSupreme-i30-c

Table of Contents