E. Fan Wiring with Remote
This appliance may be used with an RC200 or RC300
remote control. See Figure 10.5.
1. Remove cord assembly spades from rheostat and
sensor switch.
NOTICE: Fan speed and operation are controlled by the
remote control. The sensor switch and rheostat are no
longer needed.
NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED,
IT MUST BE REPLACED WITH TYPE
105
C RATED WIRE.
0
NOTE: USE ZIP TIES TO RESTRAIN
THE LOOSE WIRES UNDERNEATH
THE APPLIANCE AND KEEP THEM
AWAY FROM THE BLOWER WHEEL
(FAN BLADES).
NOTE: SENSOR SWITCH AND
RHEOSTAT SPEED CONTROL MUST
BE REMOVED FROM CIRCUIT IF
SYSTEM IS CONTROLLED WITH
RC200/RC300 REMOTE.
PLUG INTO 120V
EXISTING OUTLET
DC REGULATOR
RECEPTICLE
TO CONTROL
MODULE
BLK
BLK
BLOWER
RECEPTICLE
Figure 10.5 Wiring Diagram - Fan with RC200/RC300 Remote
Heat & Glo • Grand-I35-C, Grand-I35-SP, Supreme-I30-C, Supreme-I30-SP • 2206-901 Rev. P • 6/14
BLOWER
WHT (2)
GRN (2)
BLK (2)
BLK (2)
GRN (2)
BLK (2)
AUX 300 MODULE
FAN
2. Plug two cord assembly spade connectors together.
3. Unplug fan cord assembly from standard cord assembly.
4. Plug fan cord assembly into AUX300 module.
5. Plug AUX300 module into the standard cord assembly.
F. Control Module Operation
See Section 2.H for control module operation instructions.
STEPS
1 & 2
STEPS
3 & 4
WHT
GRN
BLK
FUSE WIRE
ASSEMBLY
FUSE WIRE
ASSEMBLY
BLK
GRN
WHT
PLUG
120V EXISTING
OUTLET
STEP 5
SENSOR SWITCH
SPEED CONTROL
(RHEOSTAT)
BLK
GRN
BLK
BLOWERS
BLK
GRN
BLK