Models:
GRAND-I35
GRAND-I35-SP
SUPREME-I30
SUPREME-I30-SP
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Owner's Manual
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
A CO detector shall be installed in the room where the appliance
in installed.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Installation and Operation
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo SUPREME-I30-SP

  • Page 1 This appliance is only for use with the type(s) of gas indicated professionals, or technicians supervised by an NFI on the rating plate. certifi ed professional. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 2: Congratulations

    00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie): Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 3: Table Of Contents

    B. Flue Damper........21 Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 4: Limited Lifetime Warranty

    Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645C 12-29-10 Page 1 of 2 Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 5 B. Limited Lifetime Warranty (continued) WARRANTY CONDITIONS: WARRANTY EXCLUSIONS: This warranty is void if: LIMITATIONS OF LIABILITY: 4021-645C 12-29-10 Page 2 of 2 Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 6: Listing And Code Approvals

    (2000-4500 FT) 31,000 15,500 (0-2000 FT) Supreme-I30, Supreme-I30-SP (LP) CANADA 27,500 14,500 (2000-4500 FT) 35,000 17,000 (0-2000 FT) Grand-I35, Grand-I35-SP, (LP) CANADA 31,000 15,500 (2000-4500 FT) Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 7: User Guide

    (NOT SHOWN) SECTION 2.D. FIXED GLASS ASSEMBLY MANTEL (NOT SHOWN) SECTION SECTION 12.H. 5.B AND 11.A HEARTH CLEAR SPACE SECTION 2.C. Figure 2.1 General Operating Parts Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 8: Clear Space

    3. The control module has safety feature that automatically shuts down the fi replace after 9 hours of continuous operation without receiving a command from the RC300 remote. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 9: Before Lighting Fireplace

    NOTICE: If the appliance shuts down after 9 hours of continuous operation, the module must be reset. See Module Reset instructions in this section. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 10: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 11: For Your Safety

    Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. 4. Push in gas control knob slightly and turn clock- wise to OFF”. DO NOT force. 5. Close control access panel. Final inspection by 464-903H Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 12: After Appliance Is Lit

    Some optional control systems available with IPI models may allow pilot fl ame to continually? remain lit. In a standing pilot system the pilot will always stay on. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 13: Maintenance And Service

    • Carefully set fi xed glass assembly in place on appliance. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 14: Maintenance Tasks-Service Technician

    Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 15 • Verify that there is not a short in fl ame sense circuit by checking continuity between pilot hood and fl ame sense rod. Replace pilot as necessary. (IPI only) Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 16: Installer Guide

    SURROUND OR FRONT NOT SHOWN SECTION 2.D AND 8.D. HEARTH EXTENSION GAS LINE (SECTION 9) ACCESS THROUGH EXISTING MASONRY OR WOODBURNING FIREPLACE Figure 4.1 Typical System Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 17: Design And Installation Considerations

    Noncorrosive leak check solution 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure rating) Stove cement (1200ºF or higher continuous exposure rating) Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 18: Fireplace Size Requirements

    **Unit depth is measured to the back of the surround to give the depth needed for installation. In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B). Figure 5.1 Fireplace Opening Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 19: Mantel And Wall Projections

    fi rebox. Combustible facings must not extend behind the insert surround. For non-combustible material specifi cations refer to section 1.E. Figure 5.3 Mantel Clearances Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 20: Termination Locations

    Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 21: Installation Preparation

    • It is recommended that extra length of gas line be installed within the existing wood burner or masonry fi replace to allow removal of the insert for future servicing needs. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 22: Installing Vent Pipe And Appliance

    INLET AIR STARTING COLLAR NOTE: TO ACHIEVE OPTIMUM PERFOR- MANCE OF INSERT, MINIMIZE OR AVOID BENDS IN EXHAUST VENT PIPE. STARTING COLLAR BRACKET EXHAUST STARTING COLLAR Figure 8.1 Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 23: Placing, Securing And Leveling The Appliance

    • Push insert into the opening so that it tightly overlaps the fi replace opening. AUXILIARY 300 MODULE Figure 8.4 Location of AUX300 for Remote Control Blower Function - IPI Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 24: Installing Adaptor And Termination Cap

    VENT PIPE screws. Connect both the LINK-ZC-ADPB to Class A Pipe and the termination cap to the LINK-ZC-ADPB with the Figure 8.7 self tapping screws provided. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 25: Gas Information

    fl exible gas connector are connected to the 1/2 inch (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 26: Electrical Information

    Figure 10.1 Ignitor Button (See Installation instructions for remote control/fronts). • If desired an additional wall switch or thermostat may be added to system. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 27: Pilot Assembly

    Figure 10.2 IPI Wiring Diagram PILOT ASSEMBLY THERMOCOUPLE THERMOPILE PIEZO VALVE OPTIONAL WALL SWITCH, ROCKER THERMOSTAT OR REMOTE SWITCH Figure 10.3 Standing Pilot Ignition Wiring Diagram Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 28: Optional Accessories Requirements

    TO VALVE BROWN BLACK PLUG INTO 120V EXISTING OUTLET DC REGULATOR RECEPTACLE VARIABLE SPEED CONTROL BLOWERS BLOWER TEMPERATURE RECEPTACLE SENSOR SWITCH Figure 10.4 Fan Wiring Diagram Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 29: Fan Wiring With Remote

    PLUG INTO 120V EXISTING OUTLET DC REGULATOR RECEPTICLE BLOWERS AUX 300 MODULE TO CONTROL MODULE BLOWER RECEPTICLE Figure 10.5 Wiring Diagram - Fan with RC200/RC300 Remote Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 30: Finishing

    Combustible facings must not extend behind the insert surround. For non-combustible material specifi cations refer to section 1.E. Figure 11.1 Clearances to Mantels or other Combustibles above Appliance Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 31: Appliance Setup

    • Place lava rock in front of and to the sides of the burner. Figure 12.2 Placement of Embers PLACE LAVA ROCK IN SHADED AREA ONLY Figure 12.1 Placement of Lava Rock Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 32: Install The Log Assembly

    Log #1 (SRV2205-702) Position Log #1 as shown in Figure 3. Mate the left grate tine with the log groove. Rest the nose of the log on the log support as shown. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 33 Log #5 (SRV2205-710): Mate the notch on Log #5 with the second grate tine from the left as shown in Figure 10. Set the other end of the log on the fl at spot of Log #1. See Figure 3. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 34 Place the wider end of the log on the fl at spot of Log #2. See Figure 5 and Figure 7 for locations of fl at spots. 2205-935B Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 35 Rotate the right end of Log #2 clockwise, until it comes into contact with the grate tine. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 36 Log #6 SRV(2206-706): Position Log #6 as shown in Figure 8. See Figure 7 for additional references. Rest the left end of Log #6 on the fl at spot of Log #3. Position the nose of Log #6 on the fork of Log #5. 2206-935B Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 37: Fixed Glass Assembly

    SUPREME-I30 3/8 in. 1/2 in. GRAND-I35 3/8 in. 1/2 in. Figure 12.3 Fixed Glass Assembly Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 38: Troubleshooting

    Take a reading at the thermopile leads. The reading should be 350 millivolts minimum. Replace the thermopile if the read- ing is below the minimum. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 39 Ensure that the glass is tightened properly on the unit, particularly on top corners. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 40: Intellifire Plus™ Ignition System

    fl ame sensing rod. Verify continuity with a multi-meter with ohms set at lowest range. Replace pilot if any damage is detected. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 41: Reference Materials

    10-1/2 9-1/2 *Note: Location G on Figure 14.1 is measuring the appliance depth, for installation depth reference Location G on Figure 5.1. Figure 14.1 Appliance Dimensions Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 42: Vent Kits Components

    FLEX3-30: One 3 inch fl exible liner expands to 30 feet. FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 43 Rheostat Knob 100-512 Control Panel 2205-129 On/Off Rheostat 2206-800 Blower Assembly GFK-210 Power Cord Assembly 2206-068 Cord Assembly 2201-017 Additional service part numbers appear on following page. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 44 Rheostat Knob 100-512 Control Panel 2205-129 On/Off Rheostat 2206-800 GFK-210 Blower Assembly Power Cord Assembly 2206-068 Cord Assembly 2201-017 Additional service part numbers appear on following page. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 45 046-018A **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 500mA~10A 3/4” long Additional service part numbers appear on following page. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 46 Brass Connector Pkg of 5 303-315/5 Valve NG 2166-300 19.9 Valve LP 2166-301 19.10 Temp Sensor Assembly 046-018A Additional service part numbers appear on following page. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 47: Service Parts List

    IPI Conversion Kits Conversion Kit NG NGK-I35 Conversion Kit LP LPK-I35 Pilot Orifi ce NG 2098-520 Pilot Orifi ce LP 2098-512 Regulator NG NGK-DXV-50 Regulator LP LPK-DXV-50 Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...
  • Page 48: Contact Information

    5647340, 5890485, 5941237, 5947112, 5996575, 6006743, 6019099, 6053165, 6145502, 6170481, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729 or other U.S. and foreign patents pending. 2000-945 Printed in U.S.A. - Copyright 2011 Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11...