Page 1
Atmospheric Connectionless Steamer Self-Contained Electric Heated Capacity: 3 Steamer Pans [per cavity] (VRC-3E) 6 Steamer Pans [per cavity] (VRC-6E) THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL. FOR YOUR SAFETY...
RETURNED TO ITS PROPER LOCATION. WARNING: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT. SERVICE BY OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.
WARRANTY PROTECTION ............. . 21-22 References UNDERWRITERS LABORATORIES, INC. NATIONAL FIRE PROTECTION ASSOCIATION 333 Pfingsten Road 60 Batterymarch Park Northbrook, Illinois 60062 Quincy, Massachusetts 02269 NFPA/70 The National Electrical Code Website Address: www.groen.com NATIONAL SANITATION FOUNDATION 3475 Plymouth Road Ann Arbor, Michigan 48106...
The cavity holds up to three (VRC-3E) or six (VRC- 6E) steam table pans (12" x 20" x 2½" deep). An 18 gauge stainless steel case encloses the cavity and the control compartment that houses electrical components.
For double stack units only: Water Connection(s) By loosening the left screw and removing the right No water connection is needed. The water will be screw provided, mount steam exhaust bracket poured directly into the water cavity reservoir. Avoid assembly to the back panel of the top Vortex unit as the use of any chemically treated water specifically shown in detail “B”...
Operator controls are on the front right of the unit. becomes too hot. The VRC-3E and VRC-6E control panels have the The unit will automatically shut off, and following touch pads and indicator lights:...
Page 9
If you want to steam continuously, turn the The timer is used in three ways timer to the manual ON position. The green ON light will illuminate. The unit will continue In the HOLD position the steam steaming. generator stays at a low boil or “holding” temperature.
Cleaning To keep your VRC-3E or VRC-6E Connectionless Steamer in proper working condition, use the following procedure to clean the unit. Suggested Tools Use a mild detergent to wipe down the steamer cavity, the probes on the inside back panel wall Mild detergent and the pan racks.
Troubleshooting This Groen Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel.
Parts List To order parts, contact your authorized Groen Service Agency. Supply the model designation, serial number, part description, part number, quantity, and when applicable, voltage and phase.
Parts List Description Part Description Part Description Part Drain Pan 140452 19 Water Probe 142689 39 Insulation, Heating Element 142357 Ball Valve, ½ N.P.T. 140534 20 Motor Assembly 096740 40 Contactor 119811 Leg Appliance, 4" High 041121 21 Remote Reading Dial Thermometer 141055 41 Toroid Transformer 119856...
Page 14
VORTEX HEATING ELEMENTS REPLACEMENT KITS FOR 3 PAN MODELS 9KW 208V Part # 143320 FOR 3 PAN MODELS 9KW 240V Part # 143321 FOR 3 PAN MODELS 9KW 480V Part # 143322 FOR 6 PAN MODELS 12KW 208V Part # 143323 FOR 6 PAN MODELS 12KW 240V Part # 143324 FOR 6 PAN MODELS 12KW 480V...
WATER FILL-DRAIN KIT INSTALLATION INSTRUCTIONS 1-Remove all parts from shipping cartons. 3.8 Connect the two hose electrical leads to the solenoid valve. The leads are marked with WV-1 and WV-2. WARNING: DISCONNECT POWER BEFORE wiring harness has these two leads loose inside th unit. INSTALLING 2-Check-identify all parts as follow.
PAN RACKS FOR SINGLE STANDS ONLY INSTALLATION INSTRUCTIONS ASSEMBLY INSTRUCTIONS: 1. Unpack racks kit. 2. Identify parts. 3. Unscrew and remove screws #1 and washers #2 from the bottom of your steamer. Do not move the steamer. This will allow the bottom threaded holes to stay aligned with the holes on the stand.
Service Log Model No. Purchased From Serial No. Location Date Purchased Date Installed Purchase Order No. For Service Call Date Maintenance Performed Performed by...
(15) months from date of shipment from Groen®, whichever date first occurs (the “Warranty Period”), in accordance with the following terms and conditions: This warranty is limited to replacement parts and related labor for Groen® Equipment located at its original place of installation in the United States and Canada.
Page 22
Cost of Extended Coverage Five percent (5.0%) of the LIST PRICE of the Groen® Equipment to be covered by the Limited Extended Warranty for each additional twelve (12) months of limited extended warranty coverage. The five percent (5.0%) of the LIST PRICE charge will be the net invoice amount for each year of Limited Extended Warranty Coverage purchased.
Page 23
1055 Mendell Davis Drive OM-VRC-3E/VRC-6E Jackson, MS 39272 Part Number 141762 Rev A Telephone 601 372-3903 Revised 12/02 Fax 601 373-9587...
Need help?
Do you have a question about the Vortex VRC-3E and is the answer not in the manual?
Questions and answers