Summary of Contents for Groen GROEN HYPERSTEAM HY-6E(CE) Operator manual
Page 1
Unified Brands suggests that if you are suspicious of damage to make a notation on the delivery receipt. It will be the responsibility of the consignee to file a claim with the carrier.
Page 2
OM/SM-HY-6E(CE) IMPORTANT — READ FIRST — IMPORTANT THESE APPLIANCES MUST BE INSTALLED BY A COMPETENT PERSON IN CONFORMITY WITH THE INSTALLATION AND SERVICING INSTRUCTIONS AND NATIONAL REGULATIONS IN FORCE AT THE TIME. PARTICULAR ATTENTION MUST BE PAID TO THE FOLLOWING: I.
Page 3
OM/SM-HY-6E(CE) WARNING: WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF THE UNIT. STEAM CAN CAUSE BURNS. WARNING: BEFORE CLEANING THE OUTSIDE OF THE STEAMER, DISCONNECT THE ELECTRIC POWER SUPPLY. KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS.
OM/SM-HY-6E(CE) 1.0 - Equipment Description Your Groen HY-6E (CE) HyPerSteam Convection Steamer is designed to give years of service. It has two stainless steel cavities (cooking chambers) which are served by twin, independent atmospheric steam generators which are electrically-heated. A powerful blower circulates the steam in each cavity to increase heating efficiency.
OM/SM-HY-6E(CE) 3.0 - Water Conditioning It is essential to supply the steam generator with 3.2 If your water contains scale-forming minerals, as water that will not form scale. Even though the steam most water does, use a well-maintained water generator is engineered to minimize scale formation, softener.
OM/SM-HY-6E(CE) 4.0 - Installation and Start-Up WARNING THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES. CAUTION DO NOT INSTALL THE UNIT WITH THE RIGHT SIDE VENTS BLOCKED OR WITHIN 30 CENTIMETERS OF A HEAT SOURCE (SUCH AS A BRAISING PAN, DEEP FRYER, CHAR BROILER, OR KETTLE).
Page 8
OM/SM-HY-6E(CE) WARNING TO AVOID DAMAGE OR INJURY, FOLLOW THE ELECTRICAL SCHEMATIC EXACTLY WHEN CONNECTING THE UNIT. HY-6E (CE) HyPerSteam™ convection steamers operate at 400 Volts (Three Phase) or 230 Volts (One Phase). ELECTRICAL SUPPLY CONNECTIONS Model Voltage Maximum Kw Field Wiring Current Demands 400 - 3 Phase 10 AWG...
OM/SM-HY-6E(CE) 5.0 - Operation WARNING ANY POTENTIAL USER OF THE EQUIPMENT SHOULD BE TRAINED IN SAFE AND CORRECT OPERATING PROCEDURES. 5.1 Controls When a cook time is set, the unit steams until the timer reaches OFF. The steaming stops, a red light comes on and a beeper sounds.
Page 10
OM/SM-HY-6E(CE) 5.2.5 Open the door. Remove the pans from the 5.2.6 To shut down the unit, press the ON steamer, using hot pads or oven mitts to protect switch/pad to OFF. The steam generator will your hands from the hot pans. automatically drain.
OM/SM-HY-6E(CE) 6.0 - Cleaning To keep your HY-6E Steamer in proper working condition/order, use the following procedure to clean the unit. This regular cleaning will reduce the effort required to clean the steam generators and cavities. 6.1 Suggested Tools WARNING 1.
Page 12
OM/SM-HY-6E(CE) 6.2.2 Steam Generator and Cooking Chamber 7. Replace fan baffle partition and close door. 8. The cleaning cycle consists of a boiling clean The steamer cavity and steam generator may be cleaned separately. When cleaning is scheduled, or stage, a soak stage, and a rinse stage. The full if theSERVICE light is on, follow these simple de- cycle takes about 50 minutes to complete.
OM/SM-HY-6E(CE) 7.0 - Maintenance The HY-6E Steamer is designed for minimum 2. Inspect the cooking chamber drain to be sure maintenance, and no user adjustments should be it is not blocked. necessary. Certain parts may need replacement after prolonged use. If there is a need for service, 3.
OM/SM-HY-6E(CE) 9.0 - Parts List 9.1 External Cabinet and Sheet Metal Description Part No. Description Part No. Lower Side Panels 125899 Door Pin Lock Nut 003823 Lower Front Panel 125898 Timer Knob 123100 Adjustable Table Leg 042505 Mylar Overlay Plate 123128 Door 094150...
Page 15
OM/SM-HY-6E(CE) 9.0 - Parts List 9.2 Cavity Control Section Description Part No. Description Part No. Top Cover Clip 123150 1-3/8” Hose Clamp 127525 Timer 100983 Fan Motor 096740 Door Switch 096857 Motor Capacitor 096813 Ready Thermostat 088865 Cover, Control Panel 119806 Steam Port 088874...
Page 16
OM/SM-HY-6E(CE) 9.0 - Parts List 9.3 Steamer Base Section Description Part No. Description Part No. Terminal Block 096810 Control Transformer 120/208/240 121716 Volt Pri. 24 Volt Sec. 150VA Fuse Block 096809 Fuse 20 Amp 071849 Hi-Heat Contactor 119811 Water Level Probes 070178 Harnesses (see pg 21) Heater Assy (with hi limit t-stat)
Page 17
OM/SM-HY-6E(CE) 9.0 - Parts List 9.4 Steamer Base - Rear View Description Part No. Description Part No. Outer Steam Generator 096719 Drain Box 096791 Inner Steam Generator 096719 Drain Box Flap 099213 Top Steam Hose 099952 Drain Box Cover 096792 Bottom Steam Hose 099951 Top Cavity Drain Hose...
Page 18
OM/SM-HY-6E(CE) 9.0 - Parts List 9.5 Steamer Motor and Controls Description Part No. Description Part No. Fan Motor 096740 Timer Knob 123100 Motor Mounting Plate 094134 Door Switch 096857 Motor Shaft Seal 096868 Steam Port Kit* 118102 Motor Insulator 094135 -Ready Thermostat 088865 096790...
Page 19
OM/SM-HY-6E(CE) 9.0 - Parts List 9.6 Steamer Generator Individual Parts Description Description Steam Generator Weldment 096887 Top Steam Hose 099953 Right Steam Gen. Insulation* 096896 Sink Drain Hose 099915 Left Steam Gen. Insulation* 096770 Water Inlet Hose 096772 Safety Valve 106392 Inner Steam Generator Hose 099912...
Page 20
OM/SM-HY-6E(CE) 9.0 - Parts List 9.7 Steamer Individual Parts Description Part No. Description Part No. Heater Element, 240V 121706 Water Inlet Valve 3-way 090827 Heater Element, Gasket 042366 Control Transformer 120/208/240 Volt 121716 Pri. 24 Volt Sec. 150VA High Limit Thermostat 122009 Thermostat Clamp 093482...
OM/SM-HY-6E(CE) 10 - Service Information: The following procedures are based upon having access to the steamer on all four sides. If the steamer is installed between other appliances and there is not enough room on the sides for access, the steamer must then be pulled out from its position to gain proper access.
Page 22
OM/SM-HY-6E(CE) 5. Attach new drain valve to valve bracket. Pull silicone 7. From the back of the steamer, remove the two 8-32 hose through drain valve and loosely install hose screws holding the valve assembly in place. Lower the clamps over both ends of the hose. Be sure silicone valve.
Page 23
OM/SM-HY-6E(CE) 2. Lift the cover of the drain box. There are no fasteners To Install: holding the cover on the drain box. 10. Carefully wrap the thermal blanket onto the steam 3. Tip the cover and note there is a circular hole in the generator.
Page 24
OM/SM-HY-6E(CE) 3. Unplug the six terminals for the high heat elements 16. Using a socket wrench (with extension) tighten the on the heater plate. Note which wires (in the harness) nuts to the threaded studs. go to which terminals. Both the terminals and wires are numbered I to 6.
Page 25
OM/SM-HY-6E(CE) 10.13 Supply Voltage Terminal Block - P/N 096810 P/N 119811 Fuse - P/N 096809 1. Turn off power to the steamer. Fuse 20 Amp - P/N 071489 2. Remove the front lower panel. 1. Turn off the power to the steamer. 3.
Page 26
OM/SM-HY-6E(CE) corresponding hole punched into the front panel. This 10.18 Fan Motor Assembly Motor Insulation hole may be seen from the inside of the compartment P/N 096740 P/N 094135 only when the timer is removed. Motor Shaft Seal Oil Slinger Washer P/N 096868 P/N 096831 To Install:...
Page 27
OM/SM-HY-6E(CE) 13. The entire assembly may now be positioned on the steam port. Loosen hose and remove from steam four threaded stud bolts protruding from the cavity port. wall. Fasten the assembly with the 1/4-20 Keps nuts using a socket wrench. Make sure that the green 3.
Page 28
OM/SM-HY-6E(CE) 5. The hose may be removed. Be careful that the hose clamps do not fall off and get lost. 8. You should be able to pull a dollar bill or comparable piece of paper smoothly between the gasket and oven IMPORTANT: Make sure that the correct part (and cavity with the door closed.
Page 29
OM/SM-HY-6E(CE) 8. Remove screws and U-channel from the door. Take leaks around the door, recheck door alignment, and if the magnet and block assembly from present necessary, door gasket installation. location and place it at the opposite end of the door channel, with the magnet facing outward from the 10.26 Door Gasket...
Page 30
OM/SM-HY-6E(CE) 1. Turn steamer off and allow it to cool. position. Check that spring opens when door handle is pushed up. 2. Remove screws and U-channel from the door. 10. Apply Locktite 242 to U-channel mounting screws, 3. Remove screws, door handle, and cam. then install the screws.
12 - Service Log Model No. Purchased From Serial No. Location Date Purchased Date Installed Purchase Order No. For Service Call Date Maintenance Performed Performed by OM/SM-HY-6E(CE)
Limited Warranty To Commercial Purchasers* (for Areas Outside of the U.S. and Canada) Groen Foodservice Equipment ("Groen Equipment") has been skillfully manufactured, carefully inspected and packaged to meet rigid standards of excellence. Groen warrants its Equipment to be free from defects in material and workmanship for twelve months from date of installation or eighteen months from date of shipment with the following conditions and subject to the following limitations.
Page 34
1055 Mendell Davis Drive • Jackson MS 39272 888-994-7636 • 601-372-3903 • Fax 888-864-7636 groen.com PART NUMBER 128717, REV. B (4/06)