Timeout values
The switch timeout values determine the timeout values for all ports on the switch.
switch timeout parameters. The timeout values must be the same for all switches in the fabric.
NOTE:
Mismatched timeout values will disrupt the fabric. These should not be changed unless absolutely
necessary. Therefore, the switch must be offline to change these values. Use the Switch Properties dialog to
take the switch offline.
Table 12
Timeout values
Parameter
R_A_TOV
E_D_TOV
Interop mode
Interop mode permits interoperability with other switches in the following environments:
•
Standard: Permits interoperability with FC-SW-2 compliant switches and McDATA switches in Open
Fabric Mode. Valid domain IDs are 97–127.
•
McDATA Fabric Mode: Permits interoperability with other McDATA switches in McDATA Fabric Mode.
Valid domain IDs are 1–31.
Enabling the 239 Domain Support option extends the valid domain IDs to 1–239 for both Standard and
McDATA Fabric Mode settings. However, all switches in the fabric must support 239 domain IDs.
System services
The System Services dialog provides a central location for you to enable or disable any of the external user
services such as SNMP, Secure Sockets Layer (SSL), Secure SHell (SSH), embedded switch management
application (McDATA Web Server or Element Manager), CLI, Network Time Protocol (NTP), and Common
Information Model (CIM). Select Switch > Services to display the System Services dialog shown in
Figure
32.
Figure 32
System services dialog
Description
Resource Allocation Timeout
delayed in the Fabric and still be delivered. The default is 10000 milliseconds.
Error Detect Timeout
—R
between two N_Ports could require. The default is 2000 milliseconds.
McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide
—
Represents the maximum time a frame could be
epresents the maximum round trip time that an operation
Table 12
describes the