HP SAN Switch User Manual page 61

4gb san switch for p-class bladesystem
Table of Contents

Advertisement

Table 8
Switch data window entries (Continued)
Entry
Status
Operational State
Administrative State
Configured Admin State
Beacon Status
Reason for Status
Temperature
Fan 1 Status
Fan 2 Status
Fan 3 Status
Power Supply 1 Status
Power Supply 2 Status
Temp Failure Port Shutdown
Warning Temperature
Failure Temperature
Diag Status
Diag Fault Code
Test Status
Test Fault Code
Network
IP Address
Subnet Mask
Gateway
SNMP Enabled
Broadcast Support
NTP Client Enabled
NTP Server Address
Use Front Port
Description
Switch operational state: Online, Offline, Diagnostic, Down
Current switch administrative state
Switch administrative state that is stored in the switch configuration
Beacon status. Switch LEDs are blinking (On) or not (off).
Additional status information
Internal switch temperature °C
Not applicable.
Not applicable.
Not applicable.
Switch power status
Not applicable.
Port shutdown status when failure temperature is exceeded.
Temperature threshold (65° Celsius) above which a warning
condition alarm is generated.
Temperature threshold (70° Celsius) above which a failure condition
alarm is generated.
Diagnostic status
Not applicable.
Not applicable.
Not applicable.
Internet Protocol address
Mask that determines the IP address subnet
Gateway address
SNMP enabled or disabled.
Broadcast support status. Broadcast support is enabled (default) or
disabled.
Enabled or disabled. Allows for switches to synchronize their time to
a centralized server.
The IP address of the centralized NTP server. Ethernet connection to
NTP server is required.
Not applicable.
McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide
61

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mcdata

Table of Contents