HP ProCurve Series Installation And Getting Started Manual page 14

Hewlett-packard switch installation & getting started guide
Hide thumbs Also See for ProCurve Series:
Table of Contents

Advertisement

Introducing the Switch
Front of the Switch
Switch
State
LEDs
Spd
PoE
Usr
Mdl
On
(Module
Blink orange
Status,
Off
green/
orange)
RPS Status
On
(green/
orange)
Blink orange
Off
EPS Status
On
Blink orange
(green/
orange)
Off
Fan Status
On
(green/
Blink
orange)
orange*
PoE Status
On
(green/
Off
Orange)
Blink
orange*
Blink
orange
**
Temp
On
(green/
Blink
Orange)
orange**
Auxiliary
(green)
* The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
** The blinking behavior is an on/off cycle once every 0.5 seconds, approximately.
1-6
Meaning
Indicates the port LEDs are displaying the connection speed at which each port is
operating:
• if the port LED is off, the port is operating at 10 Mbps.
• if the port LED is blinking**, the port is operating at 100 Mbps.
• if the port LED is on continuously, the port is operating at 1000 Mbps.
• If the Mode LED is on the port is providing PoE power.
• If the Mode LED is off the port is not providing PoE power.
• If the Link LED is on the port is enabled for PoE.
• If the Link LED is off the port is disabled for PoE.
• If the Link LED is blinking, the port has an error or the port is denied power due to
insufficient power.
Reserved for future development
Expansion module is plugged into expansion slot and operating correctly
Expansion module is plugged into expansion slot but has experienced a fault
Expansion module is not plugged into expansion slot
Normal operation. RPS is connected and operating correctly. RPS could be powering
the unit.
RPS is connected but has experienced a fault.
RPS is not connected or is not powered on.
Connected to an External Power Supply, and receiving power.
The External Power Supply is connected but has experienced a fault or is unplugged.
The switch is not connected to an EPS.
Normal operation, all fans are ok.
One of the unit's fans has failed. The switch Fault LED will be blinking simultaneously.
When the switch is ready to start supplying PoE power.
Should be off only during the boot process.
If any port has a internal hardware failure
If any port is denied PoE power or detecting an external PD fault
Switch temperature is normal.
An over temperature condition has been detected.
Reserved for future development

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Procurve 3500yl series6200yl

Table of Contents