Machine Control Panel - Clarke Mini-Max 26 Operator's Manual

Clarke mini-max automatic floor cleaner operator's manual
Hide thumbs Also See for Mini-Max 26:
Table of Contents

Advertisement

Machine Control Panel

Brush Up/Down Switch (see figure 1, Item A)
To lower brush head, push the brush switch to the
down position. To lower the brush head completely to
the floor, continue to hold the switch in the down
position until the travel stops (normal scrub position).
The brush motors will start and solution will flow
(provided the solution flow valve is turned "ON") when
the accelerator pedal is pressed and the machine
begins to traverse. To raise the brush head, push the
brush switch to the up position until the brush head
travel stops.
Squeegee Up/Down Switch (See figure 1, Item B)
The squeegee switch is used to raise and lower the
squeegee and to turn on and off the vacuum motor.
The vacuum motor is turned on when the switch is
placed in the middle or lower position. NOTE: When
the squeegee switch is placed in the lower
position, the vacuum motor will turn on, but the
squeegee will not lower until the accelerator
pedal is pressed and the machine begins to
traverse forward.
To raise the squeegee, place the switch in either the
middle or up position. The middle position is used
during transport to clear the vacuum hose. The
vacuum motor will stop when the switch is placed in
the up position.
Hour Meter (See figure 1, Item C)
The hour meter indicates the number of hours the
machine has operated. It runs only when the machine
is traversing forward.
Battery Meter (See figure 1, Item D)
The battery meter indicates the relative charge on the
battery pack.
B
A
Operator's Manual
Clarke
®
C
H
G
Figure 1
-MINI MAX
Forward/Neutral/Reverse Switch (See figure 1,
Item E)
The forward/neutral/reverse switch is used to select the
direction of the machine. The machine will move
forward when the switch is placed in the forward
direction, the operator is seated properly on the seat
and the accelerator pedal is pressed. The machine will
not traverse when the switch is placed in the neutral
position. The machine will travel in reverse when the
switch is placed in the reverse direction, the operator is
seated properly on the seat and the accelerator pedal
is pressed.
Solution Flow Valve (See figure 2, Item F)
The solution flow valve regulates the flow of chemical
solution to the floor. To increase the flow, slide the
handle down. To decrease the flow, slide the handle
up. To shut off the solution, slide the handle to the up
most position.
Horn Button (See figure 1, Item G)
The MINI-MAX is equipped with a horn and is activated
by the button located on the control panel. The horn
will sound automatically when the machine is reversed.
On/Off Key Switch (See figure 1, Item H)
The key switch turns "ON" the power to the control
panel. "O" is the "OFF" and "I" is the "ON".
Circuit Breakers (See figure 3, Items I, J, K, L, M, &
N
The circuit breaker reset buttons are located on the
right side of the steering column. The breakers are as
follows:
Item I - General (3.5 amp)
Item K - Water (3.5 amp)
Item M - Brush Actuator
(8amp)
D
E
Figure 2
Figure 3
Item J - Traverse (3.5 amp)
Item L - Horn (8 amp)
Item N - Squeegee
Actuator (8 amp)
F
I
J
K
L
M
N
Page -7-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mini-max 28Mini-max 30

Table of Contents