Operating the TP-125xl and TP-126xl

6.1

Capturing the EDID

The TP-125xl is programmed with a default EDID. To replace the default EDID
you can replace it with the EDID from a display device.
To capture a new EDID:
With the display device connected to the TP-125xl, press the EDID Capture
button on the front panel of the TP-125xl.
If the EDID is successfully captured the Status LED flashes slowly for a few
seconds and then lights solid. If the EDID is not successfully captured the
Status LED flashes quickly for a few seconds then lights solid when the
default EDID is loaded.
6.2

Adjusting the Level and Equalization on the TP-126xl

You can manually adjust the signal level and equalization using the trimmers on
the front of the TP-126xl to achieve an optimum picture.
To adjust the level and equalization on the TP-126xl:
1. Use a small screwdriver to slowly turn the Level trimmer clockwise to
increase or anticlockwise to reduce the signal level of the TP-126xl.
2. Use a small screwdriver to slowly turn the EQ trimmer clockwise or
anticlockwise until you achieve an optimum picture.