Kramer TP-125xl User Manual

Uxga/audio/data line transmitter uxga/audio/data line receiver

Advertisement

Quick Links

K R A ME R E LE CT R O N IC S L T D .
USER MANUAL
MODELS:
TP-125xl
UXGA/Audio/Data Line
Transmitter
TP-126xl
UXGA/Audio/Data Line
Receiver
P/N: 2900-300206 Rev 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TP-125xl and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kramer TP-125xl

  • Page 1 K R A ME R E LE CT R O N IC S L T D . USER MANUAL MODELS: TP-125xl UXGA/Audio/Data Line Transmitter TP-126xl UXGA/Audio/Data Line Receiver P/N: 2900-300206 Rev 1...
  • Page 3: Table Of Contents

    Figure 2: TP-125xl UXGA/Audio/Data Line Transmitter Rear Panel Figure 3: TP-126xl UXGA/Audio/Data Line Receiver Front Panel Figure 4: TP-126xl UXGA/Audio/Data Line Receiver Rear Panel Figure 5: Connecting the TP-125xl Transmitter and TP-126xl Receiver Figure 6: TP Pinout Wiring TP-125xl/TP-126xl – Contents...
  • Page 4: Introduction

    Introduction Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront video, audio, presentation, and broadcasting professionals on a daily basis. In recent years, we have redesigned and upgraded most of our...
  • Page 5: Getting Started

    • Avoid interference from neighboring electrical appliances that may adversely influence signal quality Position your Kramer TP-125xl and TP-126xl away from moisture, • excessive sunlight and dust This equipment is to be used only inside a building. It may only be connected to other equipment that is installed inside a building.
  • Page 6: Shielded Twisted Pair/Unshielded Twisted Pair

    Shielded Twisted Pair/Unshielded Twisted Pair We recommend the use of Kramer’s BC-SXTP skew-free, shielded Twisted Pair (STP) cable. If unshielded twisted pair (UTP) cable is preferred, use Kramer’s BC-UXTP skew-free, UTP cable. Recycling Kramer Products The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled.
  • Page 7: Overview

    Overview The TP-125xl and TP-126xl are a high-performance, TP (Twisted Pair) transmitter and receiver pair for transmitting computer graphics video, unbalanced stereo audio, and bidirectional RS-232 data signals over extended distances using CAT 5/6 cable. The TP-125xl encodes computer graphics video, unbalanced stereo audio and RS-232 data into a TP signal.
  • Page 8: Defining The Tp-125Xl/Tp-126Xl Line Transmitter And Receiver

    Unbalanced stereo audio • RS-232 data The TP-125xl encodes the video, audio and data signals and transmits them over STP cable to a TP-126xl receiver. RS-232 data and commands flow bidirectionally, allowing status requests and control of a destination unit. The RS-232 interface makes it possible to control almost any device over a transmission range of up to 250m over STP cabling.
  • Page 9: Defining The Tp-125Xl Uxga/Audio/Data Line Transmitter

    AUDIO IN 3.5mm Mini Connect to an unbalanced, stereo audio source (see Section Jack 12V DC Power Connector Connect to one of the supplied +12V DC power adapters. Center pin positive TP-125xl/TP-126xl - Defining the TP-125xl/TP-126xl Line Transmitter and Receiver...
  • Page 10: Defining The Tp-126Xl Uxga/Audio/Data Line Receiver

    UXGA OUT 15-pin HD Connect to a computer graphics video acceptor (see Section Connector (F) LINE IN RJ-45 Connector Connect to the Line Out RJ-45 connector on the TP-125xl (See Section 2.3) RS-232 Serial Port 3-pin Connect to the RS-232 device to be controlled.
  • Page 11: Connecting The Tp-125Xl And Tp-126Xl

    Figure 5: Connecting the TP-125xl Transmitter and TP-126xl Receiver To connect the TP-125xl and the TP-126xl as illustrated in Figure 1. On the TP-125xl, connect: The computer graphics video source, (for example, the graphics output ...
  • Page 12 (for example, an AV display system with speakers) The Audio Out S/PDIF RCA connector to the digital audio acceptor,  (for example, a DAT recorder) 3. Using STP cabling, connect the TP-125xl Line Out RJ-45 connector to the TP-126xl Line In RJ-45 connector (see Section 2.3).
  • Page 13: Operating The Tp-125Xl And Tp-126Xl

    Operating the TP-125xl and TP-126xl Capturing the EDID The TP-125xl is programmed with a default EDID. To replace the default EDID you can replace it with the EDID from a display device. To capture a new EDID: • With the display device connected to the TP-125xl, press the EDID Capture button on the front panel of the TP-125xl.
  • Page 14: Wiring The Twisted Pair Rj-45 Connectors

    Brown Pair 1 4 and 5 Pair 2 1 and 2 Pair 3 3 and 6 Warning: Using a TP cable that is incorrectly wired will cause permanent damage to the device TP-125xl/TP-126xl - Wiring the Twisted Pair RJ-45 Connectors...
  • Page 15: Technical Specifications

    10% to 90%, RHL non-condensing DIMENSIONS: 12.1cm x 7.18cm x 2.48cm (4.76" x 2.83" x 0.98"), W, D, H WEIGHT: 0.2kg (0.44lbs.) approx. each ACCESSORIES: 2 Power supplies OPTIONS: RK-3T 19” rack adapter, Kramer BC-UXTP cable, Kramer BC-SXTP cable TP-125xl/TP-126xl - Technical Specifications...
  • Page 17 For the latest information on our products and a list of Kramer distributors, visit our Web site where updates to this user manual may be found. We welcome your questions, comments, and feedback. Web site: www.kramerelectronics.com E-mail: info@kramerel.com SAFETY WARNING...

This manual is also suitable for:

Tp-126xl

Table of Contents