Gree GWH18AC-D3DNA1B Service Manual page 46

Refrigerant r410a
Table of Contents

Advertisement

DIAGNOSTIC CHARTS (CONT.)
Visually confirm that fan
Visually confirm that fan
blades and outdoor coil
blades and outdoor coil
are not blocked.
are not blocked.
Yes
Yes
Trace connections from
Trace connections from
OD board. Connections
OD board. Connections
ok?
ok?
Yes
Yes
Check motor windings.
Check motor windings.
Ok?
Ok?
Yes
Yes
Motor ok.
Motor ok.
Check RV connection on
Check RV connection on
outdoor board. Ok?
outdoor board. Ok?
Yes
Yes
Check RV output on outdoor
Check RV output on outdoor
board. Ok?
board. Ok?
Yes
Yes
Check RV solenoid. Ok?
Check RV solenoid. Ok?
Yes
Yes
Replace reversing valve.
Replace reversing valve.
Fig. 39 – Reversing Valve
No
No
Clear blockage
Clear blockage
No
No
Fix connection
Fix connection
No
No
Replace Motor
Replace Motor
Fig. 38 – Motors
No
No
Clean or repair the
Clean or repair the
connection
connection
No
No
Replace outdoor board
Replace outdoor board
No
No
Replace solenoid
Replace solenoid
43