Gree GWC09AB-D3DNA2D Installation Manual

Residential
Hide thumbs Also See for GWC09AB-D3DNA2D:

Advertisement

Change for Life
Thank you for choosing Residential Air Conditioners,please read this owner's
manual carefully before operation and retain it for future reference.
Split Air Conditioner
Installation Manual
Residential Air Conditioners
MODEL:
GWC09AB-D3DNA2D GWH09AB-D3DNA2D
GWC12AB-D3DNA2D GWH12AB-D3DNA2D
GWC18AC-D3DNA2D GWH18AC-D3DNA2D
GWC24AC-D3DNA2D GWH24AC-D3DNA2D

Advertisement

Table of Contents
loading

Summary of Contents for Gree GWC09AB-D3DNA2D

  • Page 1 Change for Life Split Air Conditioner Installation Manual Residential Air Conditioners MODEL: GWC09AB-D3DNA2D GWH09AB-D3DNA2D GWC12AB-D3DNA2D GWH12AB-D3DNA2D GWC18AC-D3DNA2D GWH18AC-D3DNA2D GWC24AC-D3DNA2D GWH24AC-D3DNA2D Thank you for choosing Residential Air Conditioners,please read this owner’s manual carefully before operation and retain it for future reference.
  • Page 3: Table Of Contents

    CONTENTS ■ ............1 Notices for installation ■ ..........3 Installation dimension diagram ■ ...............4 Install indoor unit ■ .............7 Install outdoor unit ■ ......9 Test operation and check after installation ■ .......10 Installation and Maintenance of Healthy Filter Never attempt. Be sure to follow this instruction The physical product may differ from the drawing in this manual for different display.
  • Page 4: Notices For Installation

    Notices for installation Caution The unit should be installed only by authorized service center according to local or government regulations and in compliance with this manual. Before installing, please contact with local authorized maintenance center. If the unit is not installed by the authorized service center, the malfunction may not be solved due to incovenient contact between the user and the service personnel.
  • Page 5 Notices for installation Select a place about 3.3ft or more away from TV set or any other electric appliance. Select a place where the filter can be easily taken out. Make sure that the indoor unit is installed in accordance with installation dimension instructions.
  • Page 6: Installation Dimension Diagram

    Installation dimension diagram Installation dimension diagram ● Indoor unit Space to the ceiling 6inch Space to the wall Above 6inch Above 6inch Above Space to the wall inch inch Above Above Space to the floor Air outlet side ● Outdoor unit Space to the obstruction Air inlet side 12inch above...
  • Page 7: Install Indoor Unit

    Installation of Indoor Unit Installation of Mounting Plate 1. Mounting plate should be installed horizontally. As the water tray's outlet for the indoor unit is two-way type, during installation, the indoor unit should slightly slant to water tray's outlet for smooth drainage of condensate.
  • Page 8: Installation Of Drain Hose

    Installation of Indoor Unit Installation of Drain Hose Connect the drain hose to the outlet pipe of the indoor unit. Bind the joint with rubber belt. outlet pipe of indoor unit outlet pipe of drain hose indoor unit rubber belt Put the drain hose into insulating tube.
  • Page 9: Installation Of Connection Pipe

    Installation of Indoor Unit Installation of Indoor Unit External connection The piping can be output from right, right rear, left side piping electric wire ● Liquid side piping or left rear. When routing the piping and wiring from the left Tailing 2 or right side of indoor unit, cut off the tailings Gas side piping...
  • Page 10: Install Outdoor Unit

    Installation of Outdoor Unit Electric Wiring Remove the handle on the right side plate of outdoor unit. Sketch map of power connection wire: Take off wire cord anchorage. Connect and fix power cord Cable-cross board to the terminal board. Wiring should fit that of indoor unit. Fix the power cord with wire clamps and then connect the Wire hole the corresponding connector.
  • Page 11 Installation of Outdoor Unit 5. Maintain the pressure for a while after finishing vacuum pumping to see if there is leakage of the system. Usually the pressure maintenance time of the air conditioner above 5000W is 5min and the pressure maintenance time of the air conditioner below 5000W is 3min. During pressure maintenance period, the rebound of pressure should not exceed 0.005Mpa (0.11lb).
  • Page 12: Test Operation And Check After Installation

    Check after Installation and Operation Test Check after Installation Has the unit been fixed firmly? The unit may drop, shake or emit noise. It may cause insufficient cooling(heating). Have you done the refrigerant leakage test? It may cause condensation. Is thermal insulation sufficient? Is water drainage satisfactory? It may cause water leakage.
  • Page 13: Installation And Maintenance Of Healthy Filter

    Installation and Maintenance of Healthy Filter(Optional) Installation of Healthy Filter Lift up the front panel from its two ends, as shown by the arrow direction, and (as shown in Fig.a) then remove the air filter. Fig. a Fig. b Attach the healthy filter onto the air filter, Air filter (as shown in Fig.b).
  • Page 16 GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 66129911448 E-mail: gree@gree.com.cn www.gree.com...