1.7.4. Leakage current test

A leakage current shall be measured under the conditions specified below, in order to confirm that the
requirements of the judgment standard are met.
1) Measuring conditions
Measuring instrument : Leakage current meter (A 1500Ω resistor shall be incorporated, together
Testing point
Condition of the set
2) Judgment standard
The leakage current measured shall be 1.5mA or less with an input of 240V AC × 1.06 +5/-0V (60Hz).

1.7.5. Insulation resistance test

An insulation resistance shall be measured under the conditions specified below, in order to confirm that
the requirements of the judgment standard are met.
(1) Measuring conditions
Measuring instrument
Testing point
Measured value readout
(2) Judgment standard : 10MΩ or more
with a bypass capacitor of 0.15µF.)
: Between the exposed metallic block (D-SUB connector) and Phases A and
B of the power source.
: A power cable shall be connected without connecting a signal generator. The
see-saw switch on the set side shall be turned ON and OFF.
: 500V DC megger
: Between the power circuit block and the exposed metallic block
(D-SUBI connector)
: A test voltage shall be applied for one minute and the resistance value
shall be read out thereafter.
5-19