•
The appliance designed for indoor installation (Indoor
Models) must be installed indoors where it is protected
from exposure to wind, rain and weather.
•
The appliance designed for outdoor installation
(Outdoor Models) must be installed outdoors. Always
consider the use of a shelter such as a garden shed in
lieu of direct exposure of the appliance to the
elements. The additional protection afforded by the
shelter will help to minimize nuisance problems with
electrical connections and will allow easier servicing of
the appliance under severe weather conditions.
1.11
CLEARANCE FROM COMBUSTIBLE
MATERIAL
This appliance is suitable for alcove (a closet without a
door) installation with minimum clearances to combustibles
as follows:
Table 1: Clearance from Combustibles
Clearances from Combustibles
TOP:
SIDES:
REAR:
VENT (Vent Adapter):
VENT (PVC/CPVC):
FRONT:
Figure 1: Wall Hung Clearance from Combustibles
PVC/CPVC/PPE Vent Pipe
Wall Hung
Floor Mount
Model
Model
0"
0"
0"
0"
0"
12"
1"
1"
0"
0"
6"
3"
1" From
outer edge
of adapter
Single Wall Vent Adapter
Figure 2: Floor Mount Clearance from Combustibles
Clearances from combustible construction are noted on the
appliance rating plate
NOTE
4